Anemomaster (Model 6113)

 

¡Ü Applications
    ¡¤ Indoor Air Quality
    ¡¤ Heat Ventilation Air Conditioning
    ¡¤ Working environment control
    ¡¤ Measurement of air velocity and static pressure in the duct

¡Ü Features
    ¡¤ Available by use only one button that print out & calulation
    ¡¤ Suitable design for measuring inside of pipe & duct
    ¡¤ Adapted Large LCD
    ¡¤ Simply process of data by the RS-232C & Analog output functions

 

Specifications

 Measuring Function

 Air velocity, Air temperature, Pressure

 Measuring Object

 Clean airflow with normal temperature and pressure

 Measuring Range

 Air velocity        : 0.1¡­50m/s
 Air temperature : 0¡­100¡É      
 Pressure          : 0¡­¡¾5kPa ..... Option

 Resolution

 Air velocity        : 0.01m/s(0¡­9.99m/s), 0.1m/s(10¡­50m/s)
 Air temperature : 0.1¡É
 Pressure          : 0.01kPa

 Accuracy

 Air velocity        : ¡¾3% of reading
 Air temperature : ¡¾1.0¡É
 Pressure          : ¡¾3% of reading

 Temperature
 compensation accuracy

 ¡¾5% FS in a temperature range of 5¡­80¡É

 Response

 Air velocity        : Approx. 1sec (90% at air velocity of 1m/s)
 Air temperature : Approx. 30sec
 Pressure          : Approx. 1sec

 Measuring Function

 Measurement Hold, Selectable Measurement Time(1, 5, 10sec), Battery Indicate,
 Measurement Unit(Velocity : m/s, FPM, Temp. : ¡É, ¢µ, Pressure : kPa),
 Maximum Memory 100data, Calculation(Max., Min., Average), Displyed Bar-Graph
 of Velocity

 Output Function

 Digital Output : RS-232C(4,800, 9,600, 19,200, 38,400bps)
 Printer Output : Measuring Data, Memory Data, Print Out of Calculation Result
 Analog Output : DC 0¡­1V (Selectable Velocity, Temperature, Pressure of 1-ch)

 Power supply

 Alkali Battery or AC Adaptor (AC100¡­240V, 50/60Hz)

 Operating temperature

 5¡­40¡É

 Dimensions

 Main body : 210 x 133 x 120mm
 Probe : ¨ª10 x 150mm
 Cable : 2000mm

 Weight

 Approx. 1000g

 Components

 Main Unit(1), Probe(1), Cable(1), Alkali Battery(6), Extension Rod(1), Built-in Thermal
 Printer & Printer Paper(1), Shoulder Strap(1), Operation Manual(1)


 
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ