The Raynger MX
family of handheld, infrared thermometers takes noncontact temperature
measurement technology into the future. Designed for ease-of-use,
unmatched performance, and featuring new laser technology, the MX is the
professional¡¯s tool of choice.
With the graphing software, you can use your computer to organize,
display, and print temperature and time data. The software also includes
the ability to store data points, continuous or manual single-point
recording, programmable time intervals, temperature scales and limits,
built-in material table of emissivity values, customizable log
locations, and displays both contact and infrared temperatures. |
|
MX2
Features
|
- Adjustable
emissivity
- 16-point
laser circle spot; meet IEC Class 2 & FDA Class II
requirements
- Max and
Min temperature
- Bar
graph display
|
|
MX4+
Features
|
- Adjustable
emissivity
- On-board
emissivity table
- 16-point
laser circle spot; meets IEC Class 2 & FDA Class II
requirements
- Audible/visible
Low Alarm
- Max and
Min temperature
- DIF and
AVG temperature
- Bar
graph display
- Data
output: RS232 or 1 mV per degree (¡ÆC or ¡ÆF)
- 100
points of datalogging
- Windows-compatiable
Data Graphing Software
- Power
Supply (70 or 220 V), RS232 Computer Cable, 1.5 m (60 in),
K therocouple probe
|
|
|
¡¡
|
RY833901
|
RY833903
|
Adjustable emissivity |
X
|
X
|
On-board emissivity
table |
|
X
|
16-point True Spot
laser circle spot; meets IEC Class 2 & FDA Class II requirements |
X
|
X
|
Audible/visible Low
Alarm |
|
X
|
Max and Min
temperature |
X
|
X
|
DIF and AVG
temperature |
|
X
|
Bar graph display |
X
|
X
|
Data output: RS232 or
1 mV per degree (¡ÆC or ¡ÆF) |
|
X
|
100 points of
datalogging |
|
X
|
Windows-compatible
Data Graphing Software |
|
X
|
Power Supply (70 or
220V), RS232 Computer Cable, 1.5 m (60 in), K thermocouple probe |
|
X
|
SPECIFICATIONS
Temperature Range
|
-30 to 900¡ÆC (-25
to 1600¡ÆF) |
Accuracy* |
¡¾0.75% of reading
or ¡¾1¡ÆC (¡¾2¡ÆF), whichever is greater |
Repeatability* |
¡¾0.5% of reading
or ¡¾1¡ÆC (¡¾2¡ÆF), whichever is greater |
Response Time |
(95%) 250 mSec |
Spectral Response |
8 to 14 ¥ìm,
thermopile detector |
Display Resolution |
tenth degree
reading up to 900¡ÆC (0.2¡ÆF to 999.8¡ÆF) |
Operating Range |
0 to 50¡ÆC (32 to
120¡ÆF) |
Relative Humidity |
10-95% RH
noncondensing @ up to 30¡ÆC (86¡ÆF) |
Power |
2 AA Batteries, DC
power for MX4 and MX4+ |
Tripod Mount |
1/4-20 UNC |
Dimensions |
200 x 170 x 50 mm
(7.9 x 6.7 x 2 inches) |
Weight |
480g (1 lb. 6 oz) |
*
only at 23¡ÆC (73¡ÆF) |
CAT
NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
RY833901 |
|
MX2 |
|
STANDARD
PORTABLE NON-CONTACT THERMOMETER |
|
Yes |
|
1,393,200
|
Including
adjustable emissivity, visible and audible high alarm, graphic display,
current and max/min temperature, hard case |
RY833903 |
|
MX4+ |
|
ENHANCED
PORTABLE NON-CONTACT THERMOMETER WITH SOFTWARE |
|
Yes |
|
2,149,200
|
Including
adjustable emissitivity, visible and audible high/low alarms, graphic
display, current and max/min temperature, Log and recall readings, 70V
AC adapter, Windows Software, RS232 cable, Type K thermocouple, probe,
hard case |
RY833905 |
|
RAYMXAPK |
|
OPTIONAL
PADDED POUCH CARRYING CASE W/ BELT CLIP
FOR Hand-Held Infrared Thermometers |
|
Yes |
|
108,000
|
RY833904 |
|
RAYMXDT |
|
OPTIONAL
WINDOWS BASED DATA GRAPHING SOFTWARE
W/RS232 CABLE RAYMXDT FOR Hand-Held Infrared
Thermometers |
|
Yes |
|
421,200
|
RY208 |
|
XXXMXPRV1 |
|
OPTIONAL
PRINTER & HARD CASE-70 ADPTR FOR
Hand-Held Infrared Thermometers |
|
Yes |
|
1,069,200
|
RY209 |
|
XXXMXPRV2 |
|
OPTIONAL
PRINTER & HARD CSE-220 ADPTR FOR
Hand-Held Infrared Thermometers |
|
Yes |
|
1,069,200
|
RY210 |
|
XXXMXCBP |
|
OPTIONAL
MX4/MX4+ PRINTER CABLE FOR
Hand-Held Infrared Thermometers |
|
Yes |
|
108,000
|
RY211 |
|
XXXMXTP |
|
OPTIONAL
THERMISTOR (NTC) PROBE FOR
Hand-Held Infrared Thermometers |
|
Yes |
|
270,000
|
RY212 |
|
XXXMXV1 |
|
OPTIONAL
70 VAC VOLTAGE ADAPTER MX4 FOR
Hand-Held Infrared Thermometers |
|
Yes |
|
108,000
|
RY213 |
|
XXXMXV2 |
|
OPTIONAL
220 VAC VOLTAGE ADAPTER MX4 FOR
Hand-Held Infrared Thermometers |
|
Yes |
|
108,000
|
RY214 |
|
XXXMXCBA |
|
OPTIONAL
ANALOG OUTPUT CABLE FOR
Hand-Held Infrared Thermometers |
|
Yes |
|
108,000
|
RY215 |
|
XXXMXCBC |
|
OPTIONAL
RS232 INTERFACE CABLE FOR
Hand-Held Infrared Thermometers |
|
Yes |
|
108,000
|
RY216 |
|
XXXMXTCK2 |
|
OPTIONAL
TYPE K T/C PROBE -25 TO 752F XXXMXTCK *C/RB
FOR Hand-Held Infrared Thermometers |
|
Yes |
|
205,200
|
RY217 |
|
XXXMXPA |
|
OPTIONAL
5 ROLLS OF PRINTER PAPER FOR
Hand-Held Infrared Thermometers |
|
Yes |
|
108,000
|
RY218 |
|
CF |
|
OPTIONAL
Close focus option for small target areas,
D:S=50:1, 6 mm (0.24 in.) diameter spot at 300 mm (11.81 in.)
FOR Hand-Held Infrared Thermometers |
|
Yes |
|
Call
031-777-1588
|
Special
Applications Option — No Additional Charge — Must be
specified at time of order |
RY811736 |
|
SZ |
|
OPTIONAL
Subzero for low temperature applications,
D:S=60:1, measures from -50¡Æ to 500¡ÆC (-58¡Æ to 932¡ÆF)
FOR Hand-Held Infrared Thermometers |
|
Yes |
|
Call
031-777-1588
|
Special
Applications Options — No Additional Charge — Must be
specified at time of order |
| |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|