The New Model
ST80-IS offers the same features as the standard ST80, but is also
approved by Factory Mutual for hazardous locations where
Intrinsic Safety is required.
ST60
ProPlus Features
30:1
Distance to Spot (D:S)
Recall
Last Reading
12
points Data Logging
Adjustable
Emissivity
8 point
circular Laser Sighting
Probe
Jack
MAX,
MIN, DIF and AVG Temp. Display
Display
Hold (7 seconds)
HI/LO
Alarm
LCD
Backlight
0.1¡ÆC/F
Temperature Display
Hard
Carrying Case
ST80
ProPlus Features
50:1
Distance to Spot (D:S)
Adjustable
Emissivity
8 point
circular Laser Sighting
Probe
Jack
MAX,
MIN, DIF and AVG Temp. Display
Recall
Last Reading
12
points Data Logging
Display
Hold (7 seconds)
HI/LO
Alarm
LCD
Backlight
0.2¡ÆC/(0.5¡ÆF)
Temperature Display
Hard
Carrying Case
ST20
Pro Features
12:1
Distance to Spot (D:S)
pre-set
at 0.95 Emissivity
Single
Point Laser Sighting
MAX
Temperature Display
Display
Hold (7 second)
LCD
Backlight
Hard
Carrying Case
ST30
Pro Features
12:1
Distance to Spot (D:S)
pre-set
at 0.95 Emissivity
8 point
circular Laser Sighting
MAX
Temperature Display
Display
Hold (7 second)
LCD
Backlight
Hard
Carrying Case
¡¡
RY7082031
RY8112091
RY8112001
RY8112081
Distance to Spot
(D:S)
30:1
50:1
12:1
12:1
Adjustable Emissivity
•
•
—
—
Emissivity
—
—
pre-set
at 0.95
pre-set
at 0.95
Offset Laser Sighting
8
point circular
8
point circular
single
point
8
point circular
Probe Jack
•
•
—
—
MAX, MIN, DIF and AVG
Temp. Display
•
•
—
—
MAX Temperature
Display
—
—
•
•
Recall Last Reading
•
•
—
—
Data Logging
12
points
12
points
—
—
Display Hold (7
seconds)
•
•
•
•
HI/LO Alarm
•
•
—
—
LCD Backlight
•
•
•
•
Temperature Display
0.1¡ÆC/F
0.1¡ÆC
0.2¡ÆC
0.2¡ÆC
Hard Carrying Case
•
•
•
•
The New
Model RY81120IS offers the same features as the standard RY8112091, but is
also approved by Factory Mutual for hazardous locations where
Intrinsic Safety is required
SPECIFICATIONS
RY7082031
RY8112091
RY8112001
RY8112081
Temperature
-32
to 600¡ÆC (-25 to 700¡ÆF)
-32
to 760¡ÆC (-25 to 1400¡ÆF)
-32
to 400¡ÆC (-25 to 750¡ÆF)
-32
to 545¡ÆC (-25 to 950¡ÆF)
Accuracy
@ 23¡ÆC (73¡ÆF) ambient operating temperature
1 %
or ¡¾1¡ÆC (¡¾2¡ÆF), whichever is greater above 23¡ÆC (73¡ÆF)
¡¾2¡ÆC
(¡¾3¡ÆF) @ -18 to 23¡ÆC (0 to 73¡ÆF)
¡¾2.5¡ÆC
(¡¾4¡ÆF) @ -26 to -18¡ÆC (-15 to 0¡ÆF)
¡¾3¡ÆC
(5¡ÆF) @ -32 to -26¡ÆC (-25 to -15¡ÆF)
Repeatability
¡Â¡¾0.5%
or ¡Â ¡¾1¡ÆC (¡¾2¡ÆF) whichever is greater
Response Time
¡Â500
mSec (95% of reading)
Ambient Operating
Range
0
to 50¡ÆC (32 to 120¡ÆF)
Power
9V
Alkaline or NiCad Battery
Weight
320g
(11 oz.)
Model
RY81120IS — Same performance as the RY8112091, but also approved
by Factory Mutual for hazardous locations where Intrinsic Safety
is required
CAT
NO.
MODEL
DEscRIPTION
AVAIL
PRICE
RY7082031
ST60 PROPLUS
NONCONTACT
INFRARED THERMOMETER -32 TO 600° C (-25 TO 750°F)
Yes
640,764
RY8112091
ST80 PROPLUS
NONCONTACT
INFRARED THEMOMETER -32 TO 760°C (-25 TO 1400°F)
Yes
824,364
RY81120IS
ST80-IS
INTRINSICALLY
SAFE NONCONTACT INFRARED THERMOMETER -32 TO 760&DEGC (-25 TO
1400°F)
Yes
1,191,564
RY8112001
ST20 PRO
NONCONTACT
INFRARED THERMOMETER -32 TO 400 °C (-25 TO 750°F)
Yes
347,004
RY8112081
ST30 PRO
NONCONTACT
INFRARED THERMOMETER -32 TO 545&DEGc (-25 TO 950&DEGF)
Yes
457,164
RY8112032
STACPRX
RTD Probe for
ST60/ST80 (-25 Deg. C to 750 Deg. C)