Features
  • Reads PRTs/RTDs to ¡¾0.025¡ÆC and thermistors to ¡¾0.005¡ÆC
  • Model 1522 logs up to 10,000 readings on-board in multiple data sets
  • INFO-CON connector allows interchangeable use of calibrated probes
  • INFO-CON eliminates errors from programming probe data
  • Reads ITS-90, DIN 385, Callendar-Van Dusen, Steinhart-Hart, and YSI 400 thermistor curves
  • Battery powered package includes: RS-232 Cable, AC Power Adapter, One INFO-CON Connector
  • RTD accuracy to ¡¾0.025¡ÆC
  • Thermistor accuracy to ¡¾0.005¡ÆC
  • Resolution to 0.001¡Æ
 
SPECIFICATIONS

Sensor Type

Pt 25 to Pt 100 Thermistor
Temperature Range -200 to 962¡ÆC Sensor Dependant
Resistance Range 0 to 400 ohms 0 to 500K ohms
Characterizations ITS-90, IEC-751 (DIN '385'), Callendar-Van Dusen  Steinhart-Hart thermistor polynomial, YSI 400 (2252 ohms)
Temperature Accuracy (meter only) -200 to 100¡ÆC: ¡¾0.025¡ÆC 0 to 50¡ÆC: ¡¾0.005¡ÆC
100 to 400¡ÆC: ¡¾0.05¡ÆC 50 to 75¡ÆC: ¡¾0.01¡ÆC
400 to 800¡ÆC: ¡¾0.1¡ÆC 75 to 100¡ÆC: ¡¾0.02¡ÆC
800 to 962¡ÆC: ¡¾0.15¡ÆC  
Operating Range 0 to 40¡ÆC
Temperature Resolution 0.001¡Æ
Measurement Period 1 second
Communications RS-232 (Model 1522 also includes infrared interface)
Memory

Model 1700 stores 6 readings in "Hold" mode:
Model 1522 logs 10,000 readings in "Auto Log" mode and 100 readings in "Demand Log" mode (memory also holds up to 25 data labels)

Display 6-digit, 7-segment LCD with 16x1 alphanumeric
Power Rechargeable NiMH batteries (AC adapter included)
Size 7.75" H x 4.2" W x 1.5" D (20 x 11 x 4 cm)
Weight 1 lb. (0.4 kg)

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
HR1700   1700   HAND HELD THERMOMETER   Yes   1,881,900
HR1522   1522   HANDHELD THERMOMETER W/DATA- LOGGING   Yes   1,881,900 
HR56276   5627-6   OPTIONAL PROBE RTD-100 Ohm 4-WIRE -200 TO 300C 6" FOR Handheld Standards Thermometer   Yes   826,200

 

HR56279   5627-9   OPTIONAL PROBE RTD-100 Ohm 4-WIRE -200 TO 300C 9" FOR Handheld Standards Thermometer   Yes   826,200

 

HR562615   5626-15-X   OPTIONAL PROBE, 100 Ohm PRT, 15", 661¡ÆC FOR Handheld Standards Thermometer   Yes   2,882,520

 

X = termination. Specify ¡°B¡± = bare wire, ¡°S¡± = Gold Spade Lugs, ¡°D¡± = 5-pin DIN for Tweener Thermometer, ¡°I¡± Info-Con connector for HR1700 & HR1522 Handheld Thermometer. 
HR9321   9321   OPTIONAL SOFT CARRYING CASE FOR Handheld Standards Thermometer   Yes   183,600

 

HR9318   9318   OPTIONAL Hard carrying case FOR Handheld Standards Thermometer   Yes   330,480

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ