Features
  • Four channels for PRT¡¯s, thermistors, and thermocouple
  • Displays eight user-selected data fields from any channel
  • Logs up to 8,000 readings with date and time stamps
  • Battery provides eight hours of continuous operation
 
SPECIFICATIONS
 

PRT/RTD

Thermistor

Thermocouple

Inputs 2 channels PRT/thermistor and 2 channels TC, or 4 channels PRT/thermistor, or 4 channels TC, specify when ordering;
PRT/thermistor channels accepts 2, 3, or 4 wires; TC inputs accept B, E, J, K, N, R, S, T, and Au-Pt TC types
Temperature Range

-189 to 960¡ÆC

-50 to 150¡ÆC

-270 to 1800¡ÆC

Measurement Range

0 to 400 ¥Ø

0 to 500 K¥Ø

-10 to 100 mV

Characterizations

ITS-90, IEC-751 (DIN '385'), Callendar-Van Dusen

Steinhart, Hart,
YSI-400

NIST Monograph 175, 3-point deviation function applied to NIST 175, 6th-order polynomial

Temperature Accuracy
(meter only)

¡¾0.004¡ÆC at -100¡ÆC

¡¾0.0025¡ÆC at 0¡ÆC

 

Ext. RJC

Int. RJC

¡¾0.006¡ÆC at 0¡ÆC

¡¾0.0025¡ÆC at 25¡ÆC

B at 1000¡ÆC

¡¾0.6¡ÆC

¡¾0.6¡ÆC

¡¾0.009¡ÆC at 100¡ÆC

¡¾0.004¡ÆC at 50¡ÆC

E at 600¡ÆC

¡¾0.07¡ÆC

¡¾0.25¡ÆC

¡¾0.012¡ÆC at 200¡ÆC

¡¾0.010¡ÆC at 75¡ÆC

J at 600¡ÆC

¡¾0.1¡ÆC

¡¾0.35¡ÆC

¡¾0.018¡ÆC at 400¡ÆC

¡¾0.025¡ÆC at 100¡ÆC

K at 600¡ÆC

¡¾0.15¡ÆC

¡¾0.4¡ÆC

¡¾0.024¡ÆC at 600¡ÆC

 

N at 600¡ÆC

¡¾0.15¡ÆC

¡¾0.3¡ÆC

 

 

R at 1000¡ÆC

¡¾0.4¡ÆC

¡¾0.5¡ÆC

 

 

S at 1000¡ÆC

¡¾0.5¡ÆC

¡¾0.6¡ÆC

 

 

T at 200¡ÆC

¡¾0.1¡ÆC

¡¾0.3¡ÆC
Temperature Resolution

0.001¡Æ

0.0001¡Æ

0.01 to 0.001¡Æ

Resistance/Voltage Accuracy

0 to 20¥Ø: ¡¾0.0005 ¥Ø

0 to 5 K¥Ø: ¡¾0.5 ¥Ø

-10 to 50 mV: ¡¾0.005 mV

20 to 400 ¥Ø: ¡¾25 ppm of rdg.

5 to 200 K¥Ø: ¡¾100 ppm of rdg.

50 to 100 mV: ¡¾100 ppm of rdg

 

200 to 500 K¥Ø ¡¾300 ppm of rdg

(Internal RJC: ¡¾0.25¡ÆC)

Operating Range

16 to 30¡ÆC

Measurement Interval

0.1 second to 1 hour; inputs may be read sequentially or simultaneously at 1 second or greater interval

Excitation Current

1 mA

2 and 10 ¥ìA, automatically selected

n/a

Display

1.3" x 5" backlit LCD graphical display

Display Units

¡ÆC, ¡ÆF, K, ¥Ø, K¥Ø, mV

Data Logging

Up to 8,000 time- and date-stamped measurements can be logged

Logging Intervals

0.1, 0.2, 0.5, 1, 2, 5, 10, 30, or 60 seconds; 2, 5, 10, 30 or 60 minutes

Averaging

Moving average of most recent 2 to 10 readings, user selectable

Probe Connection

Patented DWF Connectors accept spade lug, bare-wire, or banana plug terminations

Universal receptacle accepts miniature and standard connectors

Communications

RS-232 and IR ports included, IEEE-488 (GPIB) optional

AC Power

100 to 240V AC, 50-60 Hz, 0.4A

DC Power

12 to 16V DC, 0.5A (battery charges during operation from 14.5 to 16V DC, 1.0A)

Battery

NiMH, 8 hours operation typical without backlight, 3 hours to charge, 500 cycles

Size

4.0" H x 7.5" W x 8.2" D (102 x 191 x 208 mm)

Weight

4.5 lbs. (2 kg)

Probes

Please inquire for a wide variety of precision PRTs, Thermistors, and thermocouples

Calibration

NIST-traceable resistance certificate and NIST-traceable voltage certificate


CAT NO. MODEL DEscRIPTION AVAIL PRICE 
HR1529   1529   CHUB-E4 THERMOMETER 2TC AND 2 PRT INPUTS   Yes   6,710,580 
HR1529R   1529R   CHUB-E4 THERMOMETER, 4 PRT INPUTS   Yes   6,710,580
HR1529T   1529T   CHUB-E4 THERMOMETER 4 TC INPUTS   Yes   6,710,580
HR25061529   2506-1529   OPTIONAL IEEE OPTION FOR Precision 4-Channel Thermometer   Yes   569,160

 

HR9935S   9935-S   OPTIONAL MULTI-CHANNEL LOG WARE, SINGLEUSER FOR Precision 4-Channel Thermometer   Yes   954,720

 

HR9935M   9935M   OPTIONAL MULTI-CHANNEL LOG WARE, MULTI USER FOR Precision 4-Channel Thermometer   Yes   1,340,280

 

HR2374   2374   OPTIONAL IR DONGLE FOR Precision 4-Channel Thermometer   Yes   128,520

 

HR2375   2375   OPTIONAL THERMAL SERIAL PRINTER FOR Precision 4-Channel Thermometer   Yes   1,377,000

 

HR9322   9322   OPTIONAL RUGGED CARRYING CASE AND 12" PROBE FOR Precision 4-Channel Thermometer   Yes   431,460

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ