ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > ¿Âµµ Temperature > µ¥ÀÌÅͷΰŠData Logger
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
DK976539 Temperature Datalogger
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
The SM101/SM150 and SM175 temperature display Dataloggers offer a 3 1/2" digital display that will tell you everything you need to know before you download it. See minimum and maximum values with the press of a key. Reading recorded data on your PC is easy with the optional A015 software. Importing data into a Word document, Excel spreadsheet or Power Point presentation is a snap!
 
SPECIFICATIONS

Internal Temperature Range (DK976539/DK976538)

-30 to +122¡ÆF (-34 to + 50¡ÆC)
Internal Temperature Sensor (DK976539/DK976538) Thermistor
Internal Temperature Accuracy (DK976539/DK976538) ¡¾1.8¡ÆF, ¡¾1¡ÆC
External Temperature Range K-Thermocouple -300 to 2000¡ÆF (-184 to 1093¡ÆC), optional probe required
Probe (DK976538 & DK976537 only) Full Range Range with standard bead wire probe: -300 to 400¡ÆF (-184 to 204¡ÆC)
External Temperature Sensor (DK976538 & DK976537) 4' teflon coated K-thermocouple bead wire probe with mini connector
External Temperature Accuracy (DK976538 & DK976537) ¡¾1.8¡ÆF (¡¾1¡ÆC) (Logger only) ¡¾7.9¡ÆF (probe)
Ambient Operating Conditions -30 to +122¡ÆF (-34 to +50¡ÆC), 0 to 95% RH (non-condensing)
Download Time 1.5 min. (when logger is full)
Key Pad Functions Min/Max, ¡ÆF/¡ÆC and Display On
Response Time DK976539:12 min. to 63% of full scale; DK976537/DK976538: 1 min. to 63% of full scale
Display Resolution 0.1¡Æ resolution to 999.9; 1¡Æ resolution above 1000
Power Supply 9V alkaline battery, approx. 1 year at a 5-minute sampling at 70¡ÆF or 120V AC adapter (not included)
Sample Interval Records data in configurable 10 second to 24 hour intervals in 10 second increments
Dimensions 5 3/8" x 4 1/2" x 1 7/16" (134.4 x 114.3 x 36.8 mm)
Memory Non-volatile (retains data even when battery is removed)
Data Storage 16,128 (8,064 per channel)
Calibration User: zero point; Factory: zero and span
Display LCD, 3.5 digit
Enclosure ABS
Approvals CE
Included with instrument Battery, manual and 4' K-thermocouple probe
 NOTE: Probe included with DK976538 can be used to monitor up to 500¡ÆF. To use full range of +2000¡ÆF, A203 optional probe must be purchased (see ordering information)
DK15 Software & Download Cable Specifications
Compatible with Windows¢â 95, 98, 2000 and NT
PC Requirements PC with 386 or better microprocessor, 4M RAM, 1 free COM (serial) port, CD drive
Cable Type/Length 9 pin male D-shell to male 2.5mm stereo plug, 6' long
Computer Interface RS-232 COM (serial) port

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
DK976539   SM101   Temperature Datalogger   Yes   402,084
DK976538   SM150   Temperature Datalogger with external K-thermocouple probe   Yes   569,160

 

DK976537   SM175   Temperature Datalogger with 2 external K-thermocouple probes   Yes   670,140

 

DK015   A015   OPTIONAL DicksonWare¢â Software and Download cable FOR Temperature Dataloggers with Digital Display   Yes   145,044

 

DK157   R157   OPTIONAL AC adapter (recommended for continuous display) FOR Temperature Dataloggers with Digital Display   Yes   64,800

 

DK976520   SW400   OPTIONAL Logger Calibration Software FOR Temperature Dataloggers with Digital Display   Yes   512,244

 

DKA708   A708   OPTIONAL Carrying case FOR Temperature Dataloggers with Digital Display   Yes   55,080

 

DK712   A712   OPTIONAL Locking wall mount case FOR Temperature Dataloggers with Digital Display   Yes   108,324

 

DKX025   X025   OPTIONAL 25' Cable - for remote connection of logger to PC FOR Temperature Dataloggers with Digital Display   Yes   156,060

 

DKX050   X050   OPTIONAL 50' Cable - for remote connection of logger to PC FOR Temperature Dataloggers with Digital Display   Yes   174,420

 

DK1140041   D605   OPTIONAL 4 INCH PIERCING PROB, 5' COIL CABLE 4"X5/32")+1650F FOR Temperature Dataloggers with Digital Display   Yes   145,044

 

DK1140042   D608   OPTIONAL 5" IMMERSION PROBE, 5' COILED CABLE +1650 F FOR Temperature Dataloggers with Digital Display   Yes   163,404

 

DK1140043   A203   OPTIONAL 6" HIGH TEMPERATUR BASIC PROBE+2100 F FOR Temperature Dataloggers with Digital Display   Yes   236,844

 

DK976540   D606   OPTIONAL Angled surface probe, 5' coiled cord, +1200¡ÆF, +649¡ÆC FOR Temperature Dataloggers with Digital Display   Yes   236,844

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ