DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
| |
The durable robust temperature logger can stand up against virtually any environment. No wiring or cables required means that Nautilus85 can be easily introduced into any application.
The high temperature capabilities of the Nautilus 135 make it the ideal logger for extreme environments. It monitors high temperatures where conventional Dataloggers aren't able to survive. |
| SPECIFICATIONS — AR10261/AR10262
No. of Channels |
One. (Ambient temperature) |
Sensor type |
Negative Temperature Coefficient Thermistor (NTC) 10,000 ohms @ 25¡Æ (77¡ÆF) |
Operating Range |
-40 to 85¡ÆC (-40 to 185¡ÆF) |
Resolution |
0.4¡ÆC (0.7¡ÆF) |
Sensor Accuracy |
¡¾0.2¡ÆC (¡¾0.4¡ÆF) @25¡ÆC |
Memory Size |
32 KB | SPECIFICATIONS — AR10263/AR10264
No. of Channels |
One. (Ambient temperature) |
Sensor type |
Negative Temperature Coefficient Thermistor (NTC) 10,000 ohms @ 25¡Æ (77¡ÆF) |
Operating Range |
10 to 135¡ÆC (-50 to 275¡ÆF) |
Resolution |
0.4¡ÆC (0.7¡ÆF) |
Sensor Accuracy |
¡¾0.5¡ÆC (0.9¡ÆF) @77¡ÆC |
Memory Size |
32 KB |
CAT NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
AR10261 |
|
NTL-100 (01-0261) |
|
Nautilus 85 Single Channel Temperature Datalogger with aluminum case |
|
Yes |
|
475,524
|
AR10262 |
|
NTL-101 (01-0262) |
|
Nautilus 85 Single Channel Temperature Datalogger with stainless steel case |
|
Yes |
|
548,964
|
AR10263 |
|
NTL-102 (01-0263) |
|
Nautilus 135 Single Channel Temperature Datalogger with aluminum case |
|
Yes |
|
659,124
|
AR10264 |
|
NTL-103 (01-0264) |
|
Nautilus 135 Single Channel Temperature Datalogger with stainless steel case |
|
Yes |
|
732,564
|
AR10275 |
|
NTL-WIN (01-0275) |
|
OPTIONAL Nautilus interface package with software & download cable FOR Thermistor Single Channel Temperature Dataloggers |
|
Yes |
|
236,844
|
AR10276 |
|
NTL-UPGRADE (01-0276) |
|
OPTIONAL Nautilus Windows software upgrade for enhanced analysis FOR Thermistor Single Channel Temperature Dataloggers |
|
Yes |
|
71,604
|
AR340017 |
|
TR-EXPRESS-FULL |
|
OPTIONAL TrendReader Express full install software is for new users of JR without any previous version of ACR software (CD format) FOR Thermistor Single Channel Temperature Dataloggers |
|
Yes |
|
145,044
|
AR340018 |
|
TR-EX-VALU-UPGRD |
|
OPTIONAL TrendReader Express Value upgrade software FOR Thermistor Single Channel Temperature Dataloggers |
|
Yes |
|
108,324
|
For users of JR. Loggers who want to upgrade their old software versions with this new product (CD format). |
AR340019 |
|
TR-EXPRESS-CONV |
|
OPTIONAL TrendReader Express Conversion FOR Thermistor Single Channel Temperature Dataloggers |
|
Yes |
|
36,720
|
Required for PC owners with no CD drive (3.5" diskette format). This product needs to be purchased with the above products. |
AR340023 |
|
TR-EX-MANUAL (34-0023) |
|
OPTIONAL TrendRead express printed manual FOR Thermistor Single Channel Temperature Dataloggers |
|
Yes |
|
55,080
| | |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
|
|