VA239403 Wall Mount Humidity and Temperature transmitter
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:VA239403
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
Wall Mount Humidity and Temperature transmitter, 4-20 mA, dual outputs.Full 0 to 100 %RH measurement
Optimal energy management

The duct and wall-mounted HMD/W 60 transmitters are designed for monitoring relative humidity and temperature in building energy management systems. The combination of high accuracy, stability and reliable operation makes these products the ideal choice for demanding energy management applications.

The duct mount transmitters can also be used in many industrial humidity monitoring applications, where their stability and resistance to chemicals and dust are of great value. A novel feature of these duct mount transmitters is the ability to remove the electronics without disassembling the unit from the duct.

Fast on-site calibration

The accuracy of the transmitters is simple to check using the humidity calibrator. The calibration can be done in seconds with a single potentiometer without disturbing operation. This saves hours of maintenance time and ensures high system accuracy. The calibrator comes complete with carrying case, calibration cables, and NIST traceable certificate.
 
Features
  • Full 0 to 100 %RH measurement
  • True two-wire transmitters with 4-20 mA loop powered output (HMD/W 60)
  • Selectable signal output of 0 to 1 V, 0 to 5 V or 0 to 10 V (HMD/W 70) with current module also 0-20 mA (HMD70)
  • Electromagnetically compatible
  • Temperature compensated
  • Excellent long-term stability
  • HUMICAP® humidity sensor for excellent accuracy and long-term stability, negligible hysteresis and resistance to dust and most chemicals.
  • Accuracy: ¡¾2% RH (0 to 90%), ¡¾3% RH (90 to 100%)
 
SPECIFICATIONS

Relative Humidity Range / Accuracy

VA2394031/VA2394011 0 to 100%; ¡¾2% 0 to 90% RH
VA239403/VA239401 0 to 95%; ¡¾2% 0 to 90% RH
Temperature Pt 1000 sensor, accuracy ¡¾0.4 ¡ÆC
Response time 90%, 15 sec. (with filter)
General
Supply voltage  10 to 35 VDC (RL = 0 ¥Ø)
20 to 35 VDC (RL = 500 ¥Ø)
Output signal 4-20 mA
General
Operating temperature range  
Electronics -5 to +55 ¡ÆC (+23 to +131 ¡ÆF)
Sensor head (duct mount) -20 to +80 ¡ÆC (-4 to +176 ¡ÆF)
Storage temperature range -40 to +80 ¡ÆC (-40 to +176 ¡ÆF)
Housing  
Sensor head (duct mount) stainless steel
Electronics (duct mount) cast aluminum
Electronics (wall mount) ABS plastic
Connections screw terminals 0.5 to 1.5 mm2
Sensor protection (duct mount)  
Standard membrane filter (17039 HM)
Optional stainless steel sintered filter HM46670
Dimensions  
Wall mount W 3.35" x H 4.33" x D 1.30"
Duct mount 3.94 x 3.94 x 2.44 Depth
Probe 9.84" x 0.47"

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
VA239403   HMW 60Y   Wall Mount Humidity and Temperature transmitter, 4-20 mA, dual outputs   Yes   1,069,200

 

Selectable signal output of 0 to 1V, 0 to 5 V or 0 to 10 V (HMD/W 70) with current module also 0-20 mA (HMD70) Available, Please inquire 
VA2394031   HMD 60Y   Duct Mount Humidity and Temperature transmitter, 4-20 mA, dual output   Yes   1,069,200

 

Selectable signal output of 0 to 1V, 0 to 5 V or 0 to 10 V (HMD/W 70) with current module also 0-20 mA (HMD70) Available, Please inquire 
VA239401   HMW 60U   Wall Mount Humidity only transmitter with single, 4-20 mA output   Yes   810,000

 

Selectable signal output of 0 to 1V, 0 to 5 V or 0 to 10 V (HMD/W 70) with current module also 0-20 mA (HMD70) Available, Please inquire 
VA2394011   HMD 60U   Duct Mount Humidity only transmitter with single, 4-20 mA output   Yes   861,840

 

Selectable signal output of 0 to 1V, 0 to 5 V or 0 to 10 V (HMD/W 70) with current module also 0-20 mA (HMD70) Available, Please inquire 
VA100381   HMI41/HMP45   OPTIONAL HUMIDITY AND TEMPERATURE INDICATOR WITH HMP45 STANDARD TEMPERATURE PROBE FOR Humidity and Temperature Transmitter   Yes   1,941,840

 

VA180   16663HM   OPTIONAL HUMICAP REPLACEMENT HUMIDITY SENSOR FOR Humidity and Temperature Transmitter   Yes   241,920

 

VA46670   46670HM   OPTIONAL STAINLESS STEEL FILTER FOR DUCT MOUNT FOR Humidity and Temperature Transmitter   Yes   97,200

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ