CS71110 Dewpoint Meter
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:CS71110
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
Dewpoint Meter. Sensor Storage - When not in use the sensor is retracted in a molecular sieve container.
Features
  • Sensor Storage - When not in use the sensor is retracted in a molecular sieve container. The sample gas pressure activates a piston which automatically moves the sensor into the sampling chamber.
  • Indicators - LCD with backlight, 3.5 digits and custom legends for units and mode, audio alert
  • Engineering Units - ¡ÆC, ¡ÆF, PPM, lbs. H2O/mm scf, gm. H2O/m3
  • Controls - 5 push buttons, all settings stored in EEprom. Manual Sensor Actuator
  • Output - Optional 4/20 mA or 0/24 mA and RS-232
  • Isolation - Sensor and case are isolated from the power supply, analog output and RS-232
  • Battery saver - Auto power off after 6 minutes
  • Pressure Correct - Programmable pressure correction button
  • Input Resolution - 0.1¡ÆC dewpoint
SPECIFICATIONS

Type

Hyper Thin Film high capacitance AL203
Dewpoint range -148¡ÆF to +68¡ÆF (-100¡ÆC to +20¡ÆC)
Accuracy ¡¾5.5¡ÆF (¡¾3¡ÆC)
Repeatability ¡¾0.9¡ÆF (¡¾3¡ÆC)
Response time For a step change from -40¡ÆC to -60¡ÆC; 63% in 90 seconds; 90% in 450 seconds
Temperature range
Sensor: -22¡ÆF to 120¡ÆF (-30¡ÆC to +50¡ÆC)
Electronics: 14¡ÆF to +120¡ÆF (-10¡ÆC to +50¡ÆC)
Storage temperature -4¡ÆF to +140¡ÆF (-20¡ÆC to +60¡ÆC)
Sample flow range Static to 100 m/s (linear velocity @ 1 atm)
Calibration method Automatic calibration, sensor saturates at dew points above +68¡ÆF (+20¡ÆC). NIST traceable factory calibration optionally available
Temperature and pressure measurements
The sample temperature is measured with a precision integrated circuit temperature sensor. Units may be optionally fitted with a pressure sensor
Mechanical
Enclosure Anodized aluminum
Dimensions 2.5" x 4.25" x 7.5"
Regulator and filter mounting facilities
Sampling chamber Electro-polished 316 stainless steel
Moving parts seals Spring energized PTFE seals
Pressure operating range Standard: 28 PSI (2 bar)
Absolute max: 100 PSI (6.9 bar)
Gas sample connections 1/4" VCO input and output ports
Power requirements 9V battery and optional 15-25 V AC or DC wall transformer

CAT NO. MODEL DEscRIPTION AVAIL PRICE
CS71110 XR7170 PORTABLE DEWPOINT MTR. 100/+20¡ÆC Yes 9,933,840
CS10024 XR10024 OPTIONAL CARRYING CASE FOR High Speed Portable Dewpoint Meter Yes 486,000

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ