DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
| |
The Battery Operated Psychrometer is completely self-contained in a high impact,resistant molded |
The Battery Operated Psychrometer is completely self-contained in a high impact, resistant molded, instrument case. Housed in this 10" x 4-1/2" x 2" case is a pair of highly accurate thermometers, a permanent accurate fan motor, a two ounce water bottle, a thermometer illuminating lamp, and a combined On/Off switch and intensity control. Externally provided with each battery operated psychrometer are an instruction manual, a humidity calculator slide rule, and a spare parts kit, which consists of extra wicking material and a lamp. All of the above are enclosed in a rugged carrying case. With the instrument removed from the carrying case, the instrument may be wall mounted and removed at any time for portable use.
The wet and dry bulb method of measuring moisture in the air is based on the evaporative cooling effect of the wet bulb. The dryer the surrounding air the more rapid water will evaporate. This causes the wet bulb to depress the temperature until a balance takes place between the cooling effect and the normal heat gain from ambient conditions. |
|
Features |
- Greater than 1% accuracy for RH determination
- Greater than 1/4% accuracy on thermometers
- Steady aspiration allows readings in 1-1/2 to 2 minutes
- Customized, high density polyethylene carrying case and spare lamp included
- Dewpoint and relative humidity readings
- Relative humidity accuracy to ¡¾1% full scale
- Requires no whirling
|
|
Applications |
- Air conditioning and heating
- Refrigeration and laboratories
- Hospitals and meteorology
- Computer rooms and printing
- Mining and transportation
- Warehousing and textile manufacturing
- Food and chemical processing
|
| | SPECIFICATIONS
Response Time |
11/2 to 2 minutes |
Psychrometric Tables |
+10¡ÆF to 140¡Æ F for relative humidity and dewpoint |
(-15¡ÆC to +44¡ÆC for relative humidity) |
Accuracy |
¡¾1% full scale |
Thermometers |
10¡ÆF to 120¡ÆF: ¡¾0.3% accuracy over entire range |
(-15¡ÆC to 45¡ÆC : ¡¾2% accuracy over entire range) |
Slide Rules |
+20¡ÆF to 120¡ÆF, -7¡ÆC to 49¡ÆC |
Battery Life |
1000 hours with 3 "D" cells |
Size |
10" x 41/2" x 2" |
Weight |
2-1/2 pound including case |
CAT NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
ET87101 |
|
22010 |
|
BATTERY OPERATED PSYCHROMETER |
|
Yes |
|
356,400 |
ET80014 |
|
80014F |
|
OPTIONAL MATCH REPLACEMENT THERMOMETER FOR Battery Operated Psychrometer |
|
Yes |
|
84,240
| | |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
|
|