The reference for HVAC units, testo 400
testo 400 |
Multi-function measuring instrument, incl. battery, Li cell and cal. protocol Used for: |
¡Ü Velocity, volume flow |
¡Ü Humidity, pressure |
¡Ü Temperature |
¡Ü CO2, rpm and current/velocity |
Part no. 0563 4001 2,537,000 ¿ø | |
Precision reference class measuring instruments have everything the professional user needs to complete complicated measurement tasks efficiently, accurately and conveniently.
testo 400 includes the parameters temperature, CO2, rpm, current, voltage, relative humidity, pressure, velocity and volume flow.
Intelligent electronics ensure the latest technology is used thanks to software updates. The measuring instrument can always keep up with the measurement tasks at hand thanks to upgrades.
Upgradable and teachable, highly reliable and of the highest quality - they are the properties which guarantee that the customer is equipped for the future.
Useful instrument functions: ¡Ü System accuracy up to 0.05 ¡ÆC and up to a resolution of 0.001 ¡ÆC ¡Ü All functions of testo 650 and testo 950 ¡Ü Input of cross-sections to volume flow calculation ¡Ü Absolute pressure compensation in thermal probes ¡Ü Density calculation for velocity measurement with reference to temperature, humidity and absolute pressure ¡Ü Turbulence degree meas. to DIN EN 27726, DIN 1946 Part 2, ISO ¡Ü Assessment of volume flow measurements with calculation of total inaccuracy of measurement in accordance with EN 12599 with VAC module (optional) | Ordering data
testo 400, multi-function measuring instrument, incl. battery, Li cell and calibration protocol Part no.0563 4001 2,537,000 ¿ø |
Barcode pen to read in measurement locations Quick and accurate allocation of reading to location Part no. 0554 0460 890,000 ¿ø |
ComSoft 3 - Professional with data management Incl. database, analysis and graphics function, data analysis, trend curve Part no. 0554 0830 617,000 ¿ø |
SoftCase (protects instrument from impact) with carrier strap, magnetic holder and probe holder Part no. 0516 0401 214,000 ¿ø SoftCase for attachable printer (protects printer from dirt/impact) Part no. 0516 0411 102,000 ¿ø |
Attachable printer (securely attached) with 1 roll of thermal paper and batteries Quickly prints readings on location Part no. 0554 0570 875,000 ¿ø |
Testo printer with 1 roll of thermal paper and 4 AA size batteries Part no. 0554 0545 456,000 ¿ø ¡Øtesto 575 fast printer, incl. 1 roll of thermal paper and batteries Part no. 0554 1775 780,000 ¿ø |
testovent 410, volume flow funnel, ¨ª 340mm/330 x 330mm, incl. case Part no. 0554 0410 578,000 ¿ø testovent 415, volume flow funnel, ¨ª 210mm/190x190mm, incl. case Part no. 0554 0415 504,000 ¿ø |
System case (plastic) Part no. 0516 0400 367,000 ¿ø
System case (aluminium) Part no. 0516 0410 569,000 ¿ø |
Measuring instrument |
Part no. |
testo 400, multi-function measuring instrument, incl. battery, Li cell and calibration protocol 2 channel multi-function measuring instrument |
0563 4001 2,537,000¿ø |
Accessories for measuring instrument |
Part no. |
Memory upgrade to 500,000 readings Upgrades memory capacity (via service) |
0554 9481 938,000 ¿ø |
Rechargeable battery set for instrument (4 rechargeables 2.4V/700mAh) Selected for quick recharging in instrument |
0554 0196 77,000 ¿ø |
Mains unit 230 V/ 8 V/ 1 A, for instrument (European plug) For mains operation and battery recharging |
0554 1084 86,000 ¿ø |
Car charging adapter, ready to measure following recharging in car Battery is recharged while travelling in car |
0554 0424 54,000 ¿ø |
Spare Li cell to save RAM data When changing battery or rechargeable battery |
0515 0028 6,000 ¿ø |
Printer and accessories |
Part no. |
Attachable printer (securely attached) with 1 roll of thermal paper and batteries |
0554 0570 875,000 ¿ø |
Testo printer with 1 roll of thermal paper and 4 AA size batteries Prints readings on location |
0554 0545 456,000 ¿ø |
¡Øtesto 575 fast printer, incl. 1 roll of thermal paper and batteries Infrared thermal line printer with graph function |
0554 1775 780,000 ¿ø |
Recharger for printer (with 4 standard rech. batt.) Rechargeable batteries are recharged externally |
0554 0110 132,000 ¿ø |
Spare thermal paper for printer (6 rolls) |
0554 0569 38,000 ¿ø |
Spare thermal paper for printer (6 rolls) Measurement data documentation legible for up to 10 years |
0554 0568 43,000 ¿ø |
Label thermal paper (Testo patent) for testo 575 printer (6 rolls), can be applied directly |
0554 0561 72,000 ¿ø | |
|
Softcase for instrument and printer |
Part no.. |
SoftCase (protects instrument from impact) with carrier strap, magnetic holder and probe holder |
0516 0401 214,000 ¿ø |
SoftCase for attachable printer (protects printer from dirt/impact) |
0516 0411 102,000 ¿ø |
Barcode and accessories |
Part no. |
Barcode pen to read in measurement locations Quick and accurate allocation of reading to location |
0554 0460 890,000 ¿ø |
Barcode labels, self-adhesive (1200 off) Location marked with barcode, printed using software |
0554 0411 89,000 ¿ø |
Adhesive pockets (50 off) for printout, paper barcode labels... |
0554 0116 115,000 ¿ø |
Software and accessories |
Part no. |
ComSoft 3 - Professional with data management Incl. database, analysis and graphics function, data analysis, trend curve |
0554 0830 617,000 ¿ø |
RS232 cable Connects instrument to PC (1.8 m) for data transfer |
0409 0178 82,000 ¿ø |
Electrical isolation for RS232 (connects measuring instrument to PC) |
0554 0006 |
VAC module |
Part no. |
Memory upgrade to 500,000 readings Upgrades memory capacity (via service) |
0554 9481 938,000 ¿ø |
VAC module upgrade Volume flow calculation in ducts with error calculation function in instrument |
0450 4010 428,000 ¿ø |
VAC module upgrade, PC software, (for ComSoft 3 software) Printout of standard measurement protocols |
0554 4030 594,000 ¿ø |
Refrigeration module |
Part no. |
Refrigeration technology" update with saved curves of all usual refrigerants |
0554 4035 311,000 ¿ø |
System case |
Part no. |
Transport case (plastic) for measuring instrument, probes |
0516 0300 148,000 ¿ø |
System case (plastic) for measuring instrument, probes and accessories Probes in lid make it easy to find parts in case |
0516 0400 367,000 ¿ø |
System case (aluminium) for measuring instrument, probes and accessories Probes in lid make it easy to find parts in case |
0516 0410 569,000 ¿ø | | Calibration certificates
Calibration certificates/Temperature |
Part no. |
ISO calibration certificate/Temperature For air/immersion probes, calibration points -18¡ÆC; 0¡ÆC; +60¡ÆC |
0520 0001 204,000 ¿ø |
ISO calibration certificate/Temperature Measuring instruments with air/immersion probe; calibration points 0¡ÆC; +150¡ÆC; +300¡ÆC |
0520 0021 230,000 ¿ø |
ISO calibration certificate/Temperature Thermometers with surface probe; calibration points +60¡ÆC; +120¡ÆC; +180¡ÆC |
0520 0071 255,000 ¿ø |
DKD calibration certificate/Temperature Meas. instr. with air/immersion probe; calibration points -20¡ÆC; 0¡ÆC; +60¡ÆC |
0520 0211 714,000 ¿ø |
DKD calibration certificate/Temperature Contact surface temperature probes; calibration points +100¡ÆC; +200¡ÆC; +300¡ÆC |
0520 0271 969,000 ¿ø |
Calibration certificates/Humidity |
Part no. |
ISO calibration certificate/Humidity Calibration points freely selectable from 5 to 95 %RH +15 to +35 ¡ÆC (max DP +70 ¡ÆC/min DP -30 ¡ÆC) -18 to +80 ¡ÆC |
0520 0106 |
ISO calibration certificate/Humidity Electronic hygrometers; calibration points 11.3%RH and 75.3%RH at +25¡ÆC |
0520 0006 242,000 ¿ø |
ISO calibration certificate/Humidity Pressure dew point measuring instruments; calibration points freely selectable -40 to 0 ¡ÆC at 6 bar |
0520 0116 |
ISO calibration certificate/Humidity Saturated saline solutions: calibration point 11.3%RH |
0520 0013 191,000 ¿ø |
ISO calibration certificate/Humidity Saturated saline solutions, calibration point 75.3%RH |
0520 0083 191,000 ¿ø |
DKD calibration certificate/Humidity Electronic hygrometers; calibration points 11.3%RH and 75.3%RH at +25¡ÆC |
0520 0206 650,000 ¿ø |
DKD calibration certificate/Humidity Calibration points freely selectable from 5 to 95%RH +25¡ÆC -18 to +70¡ÆC |
0520 0216 |
DKD calibration certificate/Humidity Saturated saline solutions; calibration point 11.3%RH |
0520 0213 332,000 ¿ø |
DKD calibration certificate/Humidity Saturated saline solutions; calibration point 75.3%RH |
0520 0283 332,000 ¿ø | |
|
Calibration certificates/Pressure |
Part no. |
ISO calibration certificate/Pressure Absolute pressure; 5 pt. distributed over the whole measurement range |
0520 0115 191,000 ¿ø |
ISO calibration certificate/Pressure Differential pressure; 5 points distributed over meas. range (-1 to 250 bar) |
0520 0005 191,000 ¿ø |
DKD calibration certificate/Pressure Differential and positive pressure; 6 measuring points distributed over meas. range (> 0.6% of fsv) |
0520 0225 255,000 ¿ø |
DKD calibration certificate/Pressure Absolute pressure; 11 measuring points distributed over meas. range (0.1 to 0.6% of fsv) |
0520 0212 612,000 ¿ø |
DKD calibration certificate/Pressure Differential and positive pressure; 11 measuring points distributed over the instrument measuring range |
0520 0215 395,000 ¿ø |
Calibration certificates/Velocity |
Part no. |
ISO calibration certificate/Velocity All velocity probes, calibration points selectable from 0.3 to 50 m/s at +25¡ÆC |
0520 0104 |
ISO calibration certificate/Velocity Hot wire, vane anemometer, Pitot tube; calibration points 1; 2; 5; 10 m/s |
0520 0004 268,000 ¿ø |
ISO calibration certificate/Velocity Hot wire, vane anemometer, Pitot tube; calibration points 5; 10; 15; 20 m/s |
0520 0034 268,000 ¿ø |
ISO calibration certificate/Velocity Hot wire, vane anemometer; calibration points 0.5; 0.8; 1; 1.5 m/s |
0520 0024 332,000 ¿ø |
DKD calibration certificate/Velocity Hot wire, vane anemometer; calibration points 0.5; 1; 2; 5; 10 m/s |
0520 0244 714,000 ¿ø |
DKD calibration certificate/Velocity Hot wire, vane anemometer, Pitot tube; calibration points 2; 5; 10; 15; 20 m/s |
0520 0204 714,000 ¿ø |
DKD calibration certificate/Velocity Hot wire anemometer; calibration points 0.1; 0.2; 0.5; 0.8; 1 m/s |
0520 0224 842,000 ¿ø | | Suitable probes at a glance
|
Part no. |
|
0610 9714 393,000 ¿ø | |
|
|
0604 9773 423,000 ¿ø |
0628 0017 750,000 ¿ø | |
|
|
0604 9794 423,000 ¿ø 0614 9794 464,000 ¿ø |
0644 1109 166,000 ¿ø |
0600 1693 161,000 ¿ø | |
|
|
|
0604 0194 303,000 ¿ø 0614 0194 |
0604 0994 319,000 ¿ø |
0604 9993 250,000 ¿ø 0614 9993 293,000 ¿ø | |
|
0604 9893 250,000 ¿ø 0614 9893 293,000 ¿ø |
0600 0394 449,000 ¿ø |
0600 5093 2,321,000 ¿ø |
0600 4793 319,000 ¿ø | |
|
0600 4893 339,000 ¿ø |
0600 1494 487,000 ¿ø |
0644 1607 159,000 ¿ø |
0600 1693 161,000 ¿ø | |
|
|
0604 9973 390,000 ¿ø 0628 0018 444,000 ¿ø | |
Accessories |
|
Silicone heat paste (14g), Tmax = +260¡ÆC Improves heat transfer in surface probes |
0554 0004 19,000 ¿ø | *with EEPROM: Precision adjustment for each probe at a measuring point; measuring range limits are saved in probe; t95 extrapolation; surface allowance in surface probe can be adapted to measuringSuitable probes at a glance
|
Part no. |
|
0600 4593 288,000 ¿ø |
0602 0092 86,000 ¿ø |
|
0628 0019 405,000 ¿ø | |
|
Part no. |
|
0604 0293 288,000 ¿ø 0614 0293 326,000 ¿ø |
0604 0493 219,000 ¿ø 0614 0493 258,000 ¿ø |
0604 0593 288,000 ¿ø 0614 0593 324,000 ¿ø |
0604 9794 423,000 ¿ø 0614 9794 |
0600 2593 607,000 ¿ø |
0600 5993 1,262,000 ¿ø |
0363 1712 | |
|
|
0604 0273 332,000 ¿ø |
0604 0274 377,000 ¿ø |
0614 0240 960,000 ¿ø |
0628 0015 706,000 ¿ø |
0628 0016 811,000 ¿ø |
0604 2573 439,000 ¿ø | |
|
Part no. |
0600 5393 186,000 ¿ø |
0600 5493 207,000 ¿ø |
0600 5793 230,000 ¿ø |
0600 5893 273,000 ¿ø |
0600 5593 423,000 ¿ø | | *with EEPROM: Precision adjustment for each probe at a measuring point; measuring range limits are saved in probe; t95 extrapolation; surface allowance in surface probe can be adapted to measuring taskSuitable probes at a glance
|
Part no. |
0554 0670 890,000 ¿ø |
Part no. |
0632 1247 890,000 ¿ø |
0632 1240 1,145,000 ¿ø |
0640 0340 732,000 ¿ø |
0554 0007 380,000 ¿ø | |
Accessories for temperature probes |
Part no. |
Cable, 1.5 m long, connects probe with plug-in head to meas. instrument PUR coating material |
0430 0143 89,000 ¿ø |
Cable, 5 m long, connects probe with plug-in head to measuring instrument PUR coating material |
0430 0145 143,000 ¿ø |
Extension cable, 5 m long, between plug-in head cable and instrument PUR coating material |
0409 0063 189,000 ¿ø | |
|
Accessories for temperature probes |
Part no. |
Telescopic handle, max. 1 m, for probe with plug-in head Cable: 2.5 m long, PUR coating material |
0430 0144 548,000 ¿ø |
Glass pipe for immersion/penetration probe to protect from corrosive agents For probes with Part nos. 0604 0273 and 0628 0015 |
0554 7072 65,000 ¿ø |
|
| |
Selecting the right temperature sensor Measuring range
|
Accuracy Select the sensor with the accuracy required for your application from the diagram or table.
Accuracy data |
Sensor |
Temp. range |
Class |
Maximum tolerances |
Fixed value |
Referred to temperature |
Thermocouple Type K (NiCr-Ni) |
-40...+1200 ¡ÆC |
2 |
¡¾2,5 ¡ÆC |
¡¾0,0075 x ltl |
-40...+1000 ¡ÆC |
1 |
¡¾1,5 ¡ÆC |
¡¾0,004 x ltl |
Type T |
-40...+350 ¡ÆC |
1 |
¡¾0,5 ¡ÆC |
¡¾0,001 x ltl |
Type J |
-40...+750 ¡ÆC |
1 |
¡¾1,5 ¡ÆC |
¡¾0,004 x ltl |
Pt100 |
-100...+200 ¡ÆC |
B |
¡¾ (0,3 + 0,005 ¡Ü ItI) |
-200...+600 ¡ÆC |
A |
¡¾ (0,15 + 0,002 ¡Ü ItI) |
NTC (Standard) |
-50...-25,1 ¡ÆC -25...+74,9 ¡ÆC +75...+150 ¡ÆC |
- |
¡¾0.4 ¡ÆC ¡¾0.2 ¡ÆC ¡¾0.5 % of reading |
NTC (High temp.) |
-30...-20,1 ¡ÆC -20...0 ¡ÆC +0,1...+75 ¡ÆC +75,1...+275 ¡ÆC |
-
- ¡ÆC |
¡¾1 ¡ÆC ¡¾0.6 ¡ÆC ¡¾0.5 ¡ÆC ¡¾0.5 ¡ÆC ¡¾0.5 % of reading |
Data for thermocouples to EN 60584-1 (formerly IEC 584-1). Two values are given. One fixed value in ¡ÆC and a formula. |
The larger value always applies. Data for Pt100 to EN 60751 (formerly IEC 751). |
There is no standardization for NTC sensors. | | | Suitable probes at a glance
|
Part no. |
|
0636 9740 750,000 ¿ø |
0636 9715 857,000 ¿ø |
0636 2130 1,148,000¿ø |
0636 9741 1,117,000¿ø |
0636 9742 816,000 ¿ø | |
|
|
0636 9840 2,708,000¿ø |
0636 9841 3,290,000¿ø |
0636 2142 1,698,000¿ø |
0628 0021 1,999,000¿ø |
0628 0022 2,086,000¿ø | |
|
|
0628 0013 1,698,000¿ø |
0636 0340 1,415,000¿ø |
0636 2140 1,275,000¿ø |
0636 0365 1,183,000¿ø |
0636 0565 370,000 ¿ø | |
* in the temperature range from +10¡ÆC to +30¡ÆC |
|
Part no. |
0638 1345 1,250,000¿ø |
0638 1445 1,015,000¿ø |
0638 1545 905,000 ¿ø |
0638 1645 905,000 ¿ø |
0638 1740 882,000 ¿ø |
0638 1840 882,000 ¿ø |
0638 1940 882,000 ¿ø | | Suitable probes at a glance
|
Part no. |
0554 0665 94,000 ¿ø |
0554 0755 77,000 ¿ø |
0554 0667 38,000 ¿ø |
0554 0757 99,000 ¿ø | |
|
0554 0666 94,000 ¿ø |
0554 0756 79,000 ¿ø |
0554 0640 77,000 ¿ø |
0554 0647 67,000 ¿ø |
0554 1031 107,000 ¿ø | |
Accessories for humidity probes/sensors |
Part no. |
Cable, 1.5 m long, connects probe with plug-in head to meas. instrument PUR coating material |
0430 0143 89,000 ¿ø |
Cable, 5 m long, connects probe with plug-in head to measuring instrument PUR coating material |
0430 0145 143,000 ¿ø |
Extension cable, 5 m long, between plug-in head cable and instrument PUR coating material |
0409 0063 189,000 ¿ø |
Telescopic handle, max. 1 m, for probe with plug-in head Cable: 2.5 m long, PUR coating material |
0430 0144 548,000 ¿ø |
Telescopic handle, 340 - 800mm long |
0430 9715 301,000 ¿ø |
Adapter for surface humidity measuring, for humidity probes ¨ª 12mm Locates damp spots on walls, for example |
0628 0012 92,000 ¿ø |
Cap for bore holes, for humidity probe with 12mm diameter Measures equilibrium moisture in bore holes |
0554 2140 87,000 ¿ø |
Control and humidity adjustment set 11.3%RH/75.3%RH incl. adapter for humidity probes
|
0554 0660 487,000 ¿ø |
Control and storage humidity (33%RH) for humidity probes |
0554 0636 216,000 ¿ø | |
|
Accessories for pressure probes |
Part no. |
Connection cable for pressure probes 0638 1740, 0638 1840, 0638 1940 |
0409 1745 201,000 ¿ø |
Magnetic holder for pressure probes For pressure probes 0638 1345/..1445/..1545/..1645 |
0554 0225 138,000 ¿ø |
Adapter for pressure probes, 1/2" outer thread, 1/4" inner thread |
0699 3127 |
|
|
|
|
|
|
|
|
|
|
|
| |
| Suitable probes at a glance
|
Part no. |
0635 9443 1,502,000 ¿ø |
0635 9540 1,556,000 ¿ø |
0635 9640 1,464,000 ¿ø |
0635 9440 1,015,000 ¿ø |
0635 9340 1,145,000 ¿ø |
0628 0036 1,313,000 ¿ø |
0635 6045 5,865,000 ¿ø | |
Accessories/Vane probes |
Part no. |
Professional telescopic handle for plug-in vane probes, max. 1 m long, extension on request |
0430 0941 543,000 ¿ø |
Extension for telescopic handle, 2 m long Please also order the 0409 0063 extension cable |
0430 0942 316,000 ¿ø |
Handle for plug-in vane probes |
0430 3545 | |
|
Accessories/Vane probes |
Part no. |
Swan neck, flexible connection between probe and connection part |
0430 0001 584,000 ¿ø |
Magnetic probe holder for vane probes |
0554 0430 250,000 ¿ø |
|
| |
|
Part no. |
0628 0035 1,030,000 ¿ø |
0635 1549 857,000 ¿ø |
0635 1049 1,145,000 ¿ø |
0635 1041 1,145,000 ¿ø | |
|
Part no. |
|
0638 1345 1,250,000 ¿ø |
0638 1445 1,015,000 ¿ø |
0638 1545 905,000 ¿ø | |
|
|
0635 2245 518,000 ¿ø |
0635 2145 245,000 ¿ø |
0635 2045 275,000 ¿ø |
0635 2345 711,000 ¿ø | | Suitable probes at a glance
|
Part no. |
|
0635 2040 474,000 ¿ø |
0635 2140 558,000 ¿ø |
0635 2240 834,000 ¿ø | |
Accessories for pressure probes |
Part no. |
Connection hose, silicone, 5m long Silicone hose connects Pitot tube and pressure probe, 5 m long |
0554 0440 72,000 ¿ø | |
|
Accessories for pressure probes |
Part no. |
Magnetic holder for pressure probes For pressure probes 0638 1345/..1445/..1545/..1645 |
0554 0225 138,000 ¿ø | |
|
|
0635 1540 1,484,000¿ø |
0628 0009 1,489,000¿ø |
0635 8888 ID No. 0699 4239/ | |
Accessories for 3-function probe |
Part no. |
Adapter for humidity adjustment of 3-function probe 0635 1540 Order with adjustment set |
0554 0661 | |
|
Accessories for 3-function probe |
Part no. |
Cable, 1.5 m long, connects probe with plug-in head to meas. instrument PUR coating material |
0430 0143 89,000 ¿ø | |
Measuring and application ranges of velocity probes | | For fast measurements on VAC systems
testo 400 with its VAC module is currently the only measuring system worldwide with which a quick and objective assessment of the functionality of a VAC system can be carried out without the need for any additional calculations. Measurement stipulations are based on internationally recognised standards; VDI 2080 in Germany, the 12599 Draft EN standard for Europe as well as Ashrae in the US. These are the first automated measurement procedures which fulfill the requirements of these standards.
The testo 400 measuring instrument is simply positioned on the ventilation duct via a magnetic holder which means that the user always has one hand free. The location data which includes location name, measurement coordinates, duct area, correction factor etc. are automatically read into the measuring instrument.
The measurement data saved in testo 400 is transmitted to your PC at the touch of a button. Time-consuming writing is eliminated, the calculations are done automatically by testo 400. The measurement results are printed using a VDI or EN standard layout. |
|
Assessment of measurement directly on location with integrated uncertainty calculation
The coordinates required for the grid measurement are shown in the instrument display. The depth information on the vane telescopic handle makes the task that much easier in practice.
|
Recommended kit: |
Part no. |
testo 400, multi-function measuring instrument, incl. battery, Li cell and calibration protocol |
0563 4001 2,537,000 ¿ø |
Memory upgrade to 500,000 readings Upgrades memory capacity (via service) |
0554 9481 938,000 ¿ø |
VAC module upgrade Volume flow calculation in ducts with error calculation function in instrument |
0450 4010 428,000 ¿ø |
ComSoft 3 - Professional with data management Incl. database, analysis and graphics function, data analysis, trend curve |
0554 0830 617,000 ¿ø |
VAC module upgrade, PC software, (for ComSoft 3 software) Printout of standard measurement protocols |
0554 4030 594,000 ¿ø |
RS232 cable Connects instrument to PC (1.8 m) for data transfer |
0409 0178 82,000 ¿ø |
Bendable vane probe (can be bent by 90¡Æ), ¨ª 100 mm, attachable to handle or telescopic handle, for measurements on ventilation outlets |
0635 9340 1,145,000 ¿ø |
Vane/temperature probe, ¨ª 16 mm, attachable to handle or telescopic handle |
0635 9540 1,556,000 ¿ø |
Professional telescopic handle for plug-in vane probes, max. 1 m long, extension on request |
0430 0941 543,000 ¿ø |
Attachable printer (securely attached) with 1 roll of thermal paper and batteries |
0554 0570 875,000 ¿ø |
SoftCase (protects instrument from impact) with carrier strap, magnetic holder and probe holder |
0516 0401 214,000 ¿ø |
SoftCase for attachable printer (protects printer from dirt/impact) Protects from impact and falls |
0516 0411 102,000 ¿ø |
System case (aluminium) for measuring instrument, probes and accessories Probes in lid make it easy to find parts in case |
0516 0410 569,000 ¿ø |
We recommend: DKD calibration certificate/Temperature El. resistance thermometer, el. thermometer; cal. points selectable from -80 to +1000¡ÆC |
0520 0201 | |
|
The specialist case for fast assessment of ventilation/air conditioning systems | Wet Bulb Globe Temperature The professional set for assessing workplaces subjected to heat
Measure with testo 400 and WBGT probe
testo 400 on-site printout e.g. with attachable printer |
Calculated WBGT and WBGTS indices are displayed directly | |
The measurement task involves assessing workplaces, particularly those subjected to heat radiation:
The WBGT probe is used to determine the WBGT (Wet Bulb Globe Temperature) climate index in accordance with DIN 33403 and ISO 7243.
The WBGT index is used to determine the maximum allowable exposure time at workplaces subjected to heat.
Possible applications are e.g.: - Steel industry - Foundries - Glass industry - Furnaces - Ceramics industry.
Heat radiation causes an increase in temperature based on: - the thermal influence of the surroundings - Work intensity - Thermal transfer of clothing - Duration of exposure.
If this burden is too high, there is a risk of a circulatory collapse, heat cramps or heat stroke. |
Three different temperatures are required in order to be able to calculate WBGT:
- Temperature of a naturally ventilated, moisturised thermometer (Tw), natural wet bulb temperature - Globe temperature (Tg) - Air temperature (Ta). The calculation is carried out inside and outside buildings without solar radiation:
WBGT = 0.7 Tw + 0.3 Tg
Outside buildings with solar radiation:
WBGTS = 0.7 Tw + 0.2 Tg + 0.1 Ta
The testo 400 measuring instrument calculates indices and shows them in the display.
The measurement should be the following for standing work: 1.7/1.1/0.1 m and 1.1/0.6/0.1 m for sedentary work.
|
The WBGT case for fast assessment of workplaces |
|
Recommended kit: |
Part no. |
testo 400, multi-function measuring instrument, incl. battery, Li cell and calibration protocol |
0563 4001 2,537,000 ¿ø |
Wet Bulb Globe temperature probe to assess workplaces subjected to heat, in accordance with ISO 7243 or DIN 33403, incl. WBGT case |
0635 8888 ID No. 0699 4239/1 |
Attachable printer (securely attached) including 1 roll of thermal paper and batteries Quickly prints readings on location |
0554 0570 875,000 ¿ø | | The professional set for comfort level measurements and occupational safety and health
The thermal well-being of humans depends to a great extent on ambient air flow. Humans react sensitively to draughts. Draught air is the most common reason for complaints about climate.
Testo¢¥s direction-independent comfort probe has been specially designed to analyse these draughts. When used together with the testo 400 reference measuring instrument, it is possible to set up a reading sequence and to calculate the corresponding mean.
However, the mean air flow alone is not sufficient to assess the effect on people. The fluctuations in ambient air flow is also important. The degree of turbulence required in the respective standards and guidelines is a measure of this. It is also calculated automatically by the testo 400 reference measuring instrument.
Standards recommend that air flow is measured directly at the workplace at a height of 0.1 m, 0.6 m and 1.1 m (for seated persons) or 0.1 m, 1.1 m and 1.7 m (for standing persons).
Th maximum mean air flow depends on the air temperature measured and the degree of turbulence calculated in each case (see graphics). |
- Draught prevention in the workplace - Measure ambient air flow in airconditioned rooms in accordance with DIN 1946 Part 2, ISO 7726 - Automatic calculation of degree of turbulence (with testo 400) - Fulfills the accuracy specifications of DIN 1946 Part 2, VDI 2080, ISO 7726 |
The normally time-consuming degree of turbulence calculation is carried out automatically by the testo 400 measuring instrument. Example: air temp.: 24.4¡ÆC, turbulence: 10% Degree of turbulence calculation: maximum mean air flow 0.26 m/s
|
testo 400 display withcalculated degree of turbulence, mean air flow and air temperature | |
Recommended kit: |
Part no. |
testo 400, multi-function measuring instrument, incl. battery, Li cell and calibration protocol 2 channel multi-function measuring instrument |
0563 4001 2,537,000 ¿ø |
Comfort level probe for measuring degree of turbulence levels, with telescope and stand. Fulfills DIN 1946 Part 2 or VDI 2080 requirements |
0628 0009 1,489,000 ¿ø |
Attachable printer (securely attached) with 1 roll of thermal paper and batteries |
0554 0570 875,000 ¿ø |
We recommend: CO2 probe measures indoor air quality and monitors the workplace. With plugin head, connection cable 0430 0143 or 0430 0145 required
|
0632 1240 1,145,000 ¿ø |
Cable, 1.5 m long, connects probe with plug-in head to meas. instrument PUR coating material |
0430 0143 89,000 ¿ø |
Standard indoor air quality probe up to +70¡ÆC Measures all physical parameters in the Mollier diagram |
0636 9740 750,000 ¿ø |
Quick-action surface probe with sprung thermocouple strip, measuring range short-term to +500¡ÆC |
0604 0194 303,000 ¿ø |
Cable, 1.5 m long, connects probe with plug-in head to meas. instrument PUR coating material |
0430 0143 89,000 ¿ø | |
|
testo 400 set up with turbulence degree probe | The Pro Set for clean room systems
Example of layout of a clean room
|
testo 400 display during the calibration of a stationary transmitter:
Left display half: Reference humidity probe Right display half: 4-20 output measurement in a transmitter using current/voltage cable (scaling 0-100%RH) | |
Defined process ambient conditions must be assured for the qualification and validation of the high quality standards of production units in clean rooms.
Air exchange and the resulting air flow are linked directly to air temperature and air moisture. Specified air flows produce defined positive pressures which prevent the ingress of impurities from outside.
Testo's measurement technology has proven to be ideal for testing process ambient conditions.
With the testo 400 reference measuring instrument, you have the possibility of connecting 2 probes simultaneously. The measuring instrument can then be used to monitor measurements on-site or for long-term measurements thanks to the integrated readings memory with capacity for 48,000 data.
Typical measurement tasks: differential pressure monitoring using the 100 Pa probe The testo 100 Pa probe with an accuracy of ¡¾(0.3 Pa + 0.5 % of the reading) is the ideal solution. Position dependencies are completely eliminated thanks to the revolutionary double membrane technology and fluctuations in temperature no longer have any influence on the measured result thanks to temperature compensation.
Accurate air temp. measurement testo 400 achieves a system accuracy of 0.1¡ÆC and a resolution of 0.01¡ÆC when used together with the precision air probe (Pt100 Class B 1/10). |
Accurate air moisture measurement The task at hand is to monitor exactly the fluctuations in air moisture with an accuracy of up to ¡¾1%RH. testo 400 sets new standards in terms of accuracy and long-term stability. The worldwide inter-laboratory test with the patented humidity sensor in leading, international institutes confirm the stated values.
Measurement of ideal air supply testo 400, with its thermal, vane and pitot tube measurements, has all the technology available to measure air flow. A calibration accuracy from 0.5% of the reading is assured thanks to the first PTB accredited DKD laboratory for flow.
Function test on lab extractors Regular testing of the air function can be carried out as a differential pressure or speed measurement in the ventilation connection above the extractor or at the sliding front opening. Based on DIN 12950 and DIN 12924, we can recommend the hot wire probe 0635 1041, vane probe ¨ª 100 mm 0635 9340 and the differential pressureprobes 0638 1345 / 0638 1445.
Stationary transmitters The check is carried out using the m©ø/h current/voltage cable (0 to 20 mA, 0 to 1 V, 0 to 10 V) and there is a possibility of integrating additional parameters. |
|
|
Recommended kit: |
Part no. |
testo 400, multi-function measuring instrument, incl. battery, Li cell and calibration protocol |
0563 4001 2,537,000 ¿ø |
Precision pressure probe, 100 Pa, measures differential pressure and velocities (in connection with Pitot tube) |
0638 1345 1,250,000 ¿ø |
Precision air probe Plug-in head, connection cable 0430 0143 or 0430 0145 required |
0628 0017 750,000 ¿ø |
Highly accurate reference humidity/temp. probe incl. calibration certificate Plug-in head, connection cable 0430 0143 or 0430 0145 required |
0636 9741 1,117,000 ¿ø |
Cable, 1.5 m long, connects probe with plug-in head to meas. instrument |
0430 0143 89,000 ¿ø |
Cable, 1.5 m long, connects probe with plug-in head to meas. instrument |
0430 0143 |
Quick-action hot wire probe, ¨ª 10 mm, with telescopic handle, for measurements in the lower velocity range with direction recognition |
0635 1041 1,145,000 ¿ø |
Bendable vane probe (can be bent by 90¡Æ), ¨ª 100 mm, attachable to handle or telescopic handle, for measurements on ventilation outlets |
0635 9340 1,145,000 ¿ø |
Professional telescopic handle for plug-in vane probes, max. 1 m long, extension on request |
0430 0941 543,000 ¿ø |
Current/voltage cable (¡¾1 V, ¡¾10 V, 20 mA) |
0554 0007 380,000 ¿ø |
System case (aluminium) for measuring instrument, probes and accessories Probes in lid make it easy to find parts in case |
0516 0410 569,000 ¿ø |
ComSoft 3 - Professional with data management Incl. database, analysis and graphics function, data analysis, trend curve |
0554 0830 617,000 ¿ø |
RS232 cable Connects instrument to PC (1.8 m) for data transfer |
0409 0178 82,000 ¿ø |
We recommend: DKD calibration certificates for temperature, humidity, velocity, pressure (See Calibration) | | Technical data
Probe type |
Vane |
Thermal |
|
|
|
Meas. range |
0... +60 m/s |
0... +20 m/s |
|
|
|
Accuracy ¡¾ 1 digit |
See Probes data for system accuracy |
¡¾0.01 m/s (0... +1.99 m/s) ¡¾0.02 m/s (+2... +4.9 m/s) ¡¾0.04 m/s (+5... +20 m/s) |
|
|
|
Resolution |
0.01 m/s (for ¨ª 60/100 mm), 0.1 m/s (for remaining probes) |
0.01 m/s (0... +20 m/s) |
|
|
|
Probe type |
Testo humid. sensor, cap. |
Pressure |
aw value |
|
|
Meas. range |
0... +100 %RH |
0... +2000 hPa |
0... +1 aW |
|
|
Accuracy ¡¾ 1 digit |
See probe data |
Probe 0638 1345 Probe 0638 1445 Probe 0638 1545 Probe 0638 1645 ¡¾0.1% of mv Probe 0638 1740 Probe 0638 1840 Probe 0638 1940 ¡¾0.2% of mv
|
See probe data |
|
|
Resolution |
0.1 %RH (0... +100 %RH) |
0.001 hPa (0638 1345 probe) 0.001 hPa (0638 1445 probe) 0.01 hPa (0638 1545 probe) 1 hPa (0638 1645 probe) 0.01 bar (0638 1740 probe) 0.01 bar (0638 1840 probe) 0.01 bar (0638 1940 probe) |
|
|
|
Probe type |
NTC |
Pt100 |
Type K (NiCr-Ni) |
Type S (Pt10Rh-Pt) |
Type J (Fe-CuNi) |
Meas. range |
-40... +150 ¡ÆC |
-200... +800 ¡ÆC |
-200... +1370 ¡ÆC |
0... +1760 ¡ÆC |
-200... +1000 ¡ÆC |
Accuracy ¡¾ 1 digit |
¡¾0.2 ¡ÆC (-10... +50 ¡ÆC) ¡¾0.4 ¡ÆC (-40... -10.1 ¡ÆC) ¡¾0.4 ¡ÆC (+50.1... +150 ¡ÆC) |
¡¾0.1 ¡ÆC (-49.9... +99.9 ¡ÆC) ¡¾0.4 ¡ÆC (-99.9... -50 ¡ÆC) ¡¾0.4 ¡ÆC (+100... +199.9 ¡ÆC) ¡¾1 ¡ÆC (-200... -100 ¡ÆC) ¡¾1 ¡ÆC (+200... +800 ¡ÆC) |
¡¾0.4 ¡ÆC (-100... +200 ¡ÆC) ¡¾1 ¡ÆC (-200... -100.1¡ÆC) ¡¾1 ¡ÆC (+200.1...+1370 ¡ÆC) |
¡¾1 ¡ÆC (0... +1760 ¡ÆC) |
¡¾0.4 ¡ÆC (-150... +150 ¡ÆC) ¡¾1 ¡ÆC (-200... -150.1 ¡ÆC) ¡¾1 ¡ÆC (+150.1... +1000 ¡ÆC) |
Resolution |
0.1 ¡ÆC (-40... +150 ¡ÆC) |
0.01 ¡ÆC (-99.9... +300 ¡ÆC) 0.1 ¡ÆC (-200... -100 ¡ÆC) 0.1 ¡ÆC (+300.1... +800 ¡ÆC) |
0.1 ¡ÆC (-200... +1370 ¡ÆC) |
1 ¡ÆC (0... +1760 ¡ÆC) |
0.1 ¡ÆC (-200... +1000 ¡ÆC) |
Probe type |
CO2 probe |
CO probe |
Mechanical |
Current/voltage measurement |
Current/voltage measurement |
Meas. range |
0... +1 Vol. % CO2 0... +10000 ppm CO2 |
0... +500 ppm CO |
+20... +20000 rpm |
0... +20 mA |
0... +10 V |
Accuracy ¡¾ 1 digit |
See probe data |
¡¾5% of mv (0... +500 ppm CO) |
(+20... +20000 rpm) |
¡¾0.04 mA (0... +20 mA) |
¡¾0.01 V (0... +10 V) |
Resolution |
|
|
1 rpm (+20...+20000 rpm) |
0.01 mA (0... +20 mA) |
0.01 V (0... +10 V) |
PC |
RS232 interface |
Memory space in basic version: 128 kB corresponds to approx. 45,000 readings |
Oper. temp. |
0... +50 ¡ÆC |
Memory space, extended: 1 MB, corresponds to approx. 500,000 readings |
Storage temp. |
-25... +60 ¡ÆC |
Other features: automatic recognition of all connected probes |
Battery type |
1.5 V AA |
Power supply: Battery/rech. batt., alternatively 8 V mains unit |
Battery life |
18 h |
Battery life in continuous operation with 2 thermocouple probes |
Weight |
500 g |
|
Warranty |
3 years |
| |
testo 400 |
- TestoÀÇ »õ·Î¿î ÇÁ·ÎÆä¼Å³Î Ŭ·¡½º
- ÂüÁ¶ ÃøÁ¤ ±â±â
Testo 400Àº Àü¹®°¡¿Í ¼÷·ÃÀÚµéÀÌ °èÃø ÀÛ¾÷À» °£ÆíÇÏ°Ô ¼öÇàÇÒ ¼ö ÀÖµµ·Ï ¼³°èµÈ ´Ù±â´É °èÃø±âÀÔ´Ï´Ù.
dz·®,ASHRAE SpeckÀÇ ÃÖ´ë ¹× ÃÖ¼Ò°ªÀ» »êÃâÇÕ´Ï´ÙmV/mA ÃøÁ¤ ÀÔ·ÂÀº Æ®·£½ºµà¼ÀÇ Ãâ·ÂÀ» ½±°Ô È®ÀÎÇÒ ¼ö ÀÖ°Ô ÇÕ´Ï´Ù. |
|
|
|
| |
|
±â´É |
Àû¿ëºÐ¾ß |
Á¤È®µµ ¡¾0.1¡É/¡ÉÀÇ ¿Âµµ ÇÁ·Îºê´Â Á¶Á¤À» À§ÇÑ ±³Á¤ ±â´ÉÀ» Á¦°ø ½Àµµ/·ÎÁ¡, ¿Ïº®ÇÑ ¸ô¸®¾î(Mollier)´ÙÀ̾î±×·¥ °ª ÁÖº¯ ·¹º§ÀÇ CO ¹× CO2 ¾Ð·Â, ¾Ð·ÂÂ÷ ¹× Àý´ë ¾Ð·Â °¡¿½Ä, º£ÀÎ ¹× ÇÇÅä°ü ÇÁ·Îºê¸¦ »ç¿ëÇÑ ¼Óµµ °èÃø °èÃø±âÀÇ ·Î°Å ±â´ÉÀ» ÀÌ¿ëÇÏ¿© Àå½Ã°£¿¡ °ÉÄ£ µ¥ÀÌÅ͸¦ ³¯Â¥, ½Ã°£ ¹× À§Ä¡¿Í ÇÔ²²·Î±ë |
dz·® °èÃø (cfm, m3/min, l/s) ³·ù(Åͺ深½º) ·¹º§ ÃøÁ¤ ÂüÁ¶°ªÀ¸·Î¼³ª ¿Ã¹Ù¸¥ ÇÇÅä°ü °èÃøÀ» À§ÇØ ¾Ð·Â (Àý´ë ¾Ð·Â)À» ÃøÁ¤ | |
|
±â¼úµ¥ÀÌÅÍ |
|
¿Âµµ |
Pt100 |
ÃøÁ¤ ¹üÀ§ |
-200 ~ +800 µµ (-328 ~ 1472 µµ) |
½Ã½ºÅÛ Á¤È®µµ |
ÃÖ´ë ¡¾0.1µµ / ¡¾0.1µµ (Class A, B) |
ÇØ»óµµ |
0.01µµ (0.01µµ) |
NiCr-Ni |
|
ÃøÁ¤ ¹üÀ§ |
-200 ~ +1,370µµ (-328 ~ +2498µµ) |
PtRh-Pt |
|
ÃøÁ¤ ¹üÀ§ |
0 ~ +1,760µµ (32 ~ +3200µµ) |
FeCu-Ni |
|
ÃøÁ¤ ¹üÀ§ |
-200 ~ +1,000µµ (-328 ~ +1832µµ) |
NTC |
|
ÃøÁ¤ ¹üÀ§ |
-50 ~ +150µµ (-58 ~ +302µµ) |
½Ã½ºÅÛ Á¤È®µµ |
ÃÖ´ë 0.4µµ (0.4µµ) |
½Àµµ °èÃø |
¡¡ |
¿Âµµ |
-30¡É ~ +180¡É (-22¡É ~ +356¡É) |
ÃøÁ¤ ¹üÀ§ |
0 ~ 100% RH |
½Ã½ºÅÛ Á¤È®µµ |
ÃÖ´ë ¡¾1.0 % RH |
¾Ð·Â °èÃø |
¡¡ |
ÃøÁ¤ ¹üÀ§ |
¡¾0.1 bar ?0.01 bar 2bar 10 bar 30 bar |
¼Óµµ °èÃø |
|
º£ÀÎ ÃøÁ¤ ¹üÀ§ |
0 ~ 60 m/s (0 ~ 12,000 fpm) |
°¡¿½Ä ÃøÁ¤ ¹üÀ§ |
0 ~ 20 m/s (0 ~ 4,000 fpm) |
ÇÇÅä°ü ÃøÁ¤ ¹üÀ§ |
0 ~ 10 mbar / 100 mbar 0 ~ 40 m/s / 100 m/s (0 ~ 8,000 / 20,000 fpm) |
dz·® (l/s, m 3 /min, m 3 /h) |
|
ÃøÁ¤ ¹üÀ§ |
360.000 cfm (1 m 2 ¿¡¼ÀÇ ÃÖ´ë »êÃâ°ª, 20,000 fpm °ª) |
CO °èÃø |
|
ÃøÁ¤ ¹üÀ§ |
0 ~ 500 ppm |
Á¤È®µµ |
¡¾5ppm |
CO 2 °èÃø |
|
ÃøÁ¤ ¹üÀ§ |
0 ~ 10,000 ppm 0 ~ 1 vol. % |
Á¤È®µµ |
ÃøÁ¤Ä¡ÀÇ ¡¾5% of m.v. ¶Ç´Â 100 ppm |
rpm °èÃø |
|
ÃøÁ¤ ¹üÀ§ |
0.333 ~ 333 Hz 20 ~ 20,000 rpm |
Á¤È®µµ |
¡¾1 ÀÚ¸® |
Àü·ù/Àü¾Ð °èÃø |
|
ÃøÁ¤ ¹üÀ§ |
0 ~ 20 mA / 4 ~ 20 mA 0 ~ ?0 V / 0 ~ ? V |
ÀÏ¹Ý ±â¼ú µ¥ÀÌÅÍ |
|
¸Þ¸ð¸® °ø°£ |
|
±âº» ¹öÀü |
¾à 7,500°³ÀÇ ÃøÁ¤°ª¿¡ ÇØ´çÇÏ´Â 15 kB |
È®Àå |
¾à 500,000°³ÀÇ ÃøÁ¤°ª¿¡ ÇØ´çÇÏ´Â 1 MB |
Àü¿ø °ø±Þ ´ëü »ç¿ë |
¹èÅ͸®/ÃæÀüÁö 8 V ÁÖÀü¿ø À¯´Ö |
ÃæÀüÁö ¼ö¸í |
18½Ã°£ (2°³ÀÇ ¼¸ÓÄ¿Çà ÇÁ·Îºê·Î ¿¬¼Ó µ¿ÀÛ) |
µ¿ÀÛ ¿Âµµ |
0 ~ +50 µµ (32 ~ +122µµ) ´Ü±â 0 ~ +60µµ (32 ~ +140µµ) |
º¸°ü/¿î¼Û ¿Âµµ |
-25 ~ +60µµ (-13 ~ +140µµ) |
¹«°Ô |
650 g (ÃæÀüÁö Æ÷ÇÔ) 1lbs. 7 ozs. |
±âŸ |
- ¿¬°áµÈ ÇÁ·Îºê ÀÚµ¿ ÀÎ½Ä - ¾÷±×·¹ÀÌµå °¡´É(Testo 650, Testo 400) - µ¥ÀÌÅÍ °ü¸®¸¦ À§ÇÑ RS 232 ÀÎÅÍÆäÀ̽º |
º¸Áõ |
±â±â : 3³â ÇÁ·Îºê : 1³â | | | | |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|
|
|