ANEMOSONICTM UA6

TOMORROWS' TECHNOLOGY TODAY

Having led the world for over 40 years in Airflow instrumentation we are proud to introduce: -

The future in Air Flow Instrumentation.

THE ANEMOSONICTM UA6

"Airflow measurement at an ultrasonic speed"

The ultrasonic technology used in the UA6 never needs re-calibration as the sensor is unaffected by airstream temperature, pressure or air/gas density

(limited only by materials of manufacture)

The UA6 measures air velocity, volume flow and airstream temperature with readings displayed in m/sec, ft/min, mph, knots, kph, cfm, m©ø/sec, ¡ÆC or ¡ÆF, all in one hand held instrument.

Having researched and developed our own unique ultrasonic technology, Airflow now offers a world first in accurate measurement for clean air and inert gas flows using a truly compact 3 pole sensor that is less than 60 mm (2.4") in diameter.

Two unique features are the rapid speed of response achieved through over 3,600 readings being taken every second and the ability to read and display percentage flow turbulence. Percentage turbulence is now being recognised as a necessity when ensuring indoor comfort levels and air quality.

With a reading response rate of less than one millisecond the AnemosonicTM UA6 ensures unequalled repeatability and accuracy in a hand held instrument offering a world beating measuring range from 0.01 m/sec (2ft/min) to 50 m/sec (9850 ft/min).

The UA6 is virtually maintenance free and can be used in damp or mildly dusty atmospheres. The three pole sensor configuration is self compensating so that even with a 40¡Æspread (¡¾ 20¡Æ) from the airstream centreline accurate measurements are still guaranteed. This superb yaw & pitch characteristic (see Tech Topic I001) makes for an invaluable instrument.

The UA6 has a built in list of user friendly options allowing everything from simple testing to long term monitoring and with the in built RS232 output, the units' readings are down loadable into a WINDOWS¢ç format for on going processing and recording.

Calibrated to an Internationally recognised standard the UA6 is supplied with a FREE TRACEABLE CALIBRATION CERTIFICATE and a reply card is also included for purchasers to register with our FREE annual calibration reminder service where an annual check is required.

All Airflow?instruments including the UA6 are designed to help meet the stringent requirements of the Control Of Substances Hazardous to Health (COSHH) and Building Regulations in the UK.

THE UA6 ADVANTAGE:

FEATURES

  • Absolute calibration for life
  • No moving parts
  • Air turbulence monitoring - a unique UA6 feature
  • Zero drift technology
  • Laser Doppler calibration
  • Exceptional Yaw and Pitch characteristics
  • Bar graph turbulence indicator
  • Compact sensor
  • Self diagnostic
  • RS232 digital and analogue outputs
  • Diagnostic microprocessor
  • Real time and stored readings
  • Manual or auto logging
  • Av/max/min with memory
  • Auto shut off
  • High clarity display and back light

APPLICATIONS

  • Test and Calibration
  • Building Energy Management Systems
  • Inert gas flows
  • Heating Ventilating and Air Conditioning
  • Process control, IAQ and environmental
  • Aeronautical R & D
  • Air and Gas flow
  • Wind Tunnel certification
  • Meteorological and wind power
  • Maritime
  • Laboratory and COSHH
  • Military
  • Tunnel ventilation
  • Offshore rigs

BENEFITS

  • Unaffected by Temperature, Pressure and relative humidity
  • Ease of use, Lightweight and Highly accurate
  • 100% repeatable readings
  • Exceptionally reliable - no moving parts
  • Saves on annual re-calibration costs
  • Mountable sensor
  • Unattended logging
  • Fast response
  • Low investment cost
  • Use in air and non hazardous gas flows
  • Rugged and durable
  • Equally accurate at high and low flows
  • Self-cleaning sensor (light dust)
  • Helps compliance with European CEN air quality requirements
  • Transfer Calibration standard.

SPECIFICATION

PARAMETER

METRIC MODE

IMPERIAL MODE

Velocity Range

0-50 m/sec

0-9999 ft/min

Volume Range

0-5000 m3/sec

0-9999 x 103 ft3 /min

Accuracy

Better than ¡¾1% of reading ¡¾1 digit

Velocity Resolution

0.01 m/sec

2 ft/min

Temperature Range

0-800C

320 to 1760F

Temperature Accuracy

¡¾1.00C

¡¾20F

Temperature Resolution

0.10C

10F

Flow Turbulence Intensity (Tu)

2-digit display 0-99% resolution 1%

Area Input Range

0.004-99.99m2

0.0431-999.9ft2

Linear Input Range
(subject to area limits)

0.0001-9999m

1/8"-9999ft

Memory Size

99 readings of velocity, temperature and turbulence
(note flow data is stored as a velocity)

Auto Logging variable time base

5 seconds to 99 minutes 59 seconds

Analogue Output

0-1 volt (0-0.5v and 0-2v also available)

Digital Output

RS232

Power Supply

4 x 1.5volt AA cells. (rechargeable, zinc carbon or alkaline)

Battery Life

20 hrs

Overall Dimensions

92 x 32 x 188mm

3.6 x 1.2 x 7.4ins

Instrument Operating
Environmental temp. range

-100C to +500C

140F to 1220F

Storage temperature range

-200C to +600C

-40F to 1400F

Ultrasonic Sensor Operating
Environment

00C to 800C

320F to 1760F

Weight (less batteries)

440g

0.97lb

Standard Kit UA6 Anemometer
Ultrasonic sensor
Handle & Telescopic extension rod with swivelling joint
0.4 to 1.1M (15" to 43")
Executive carry case
Calibration certificate
Batteries
Optional Accessories P.C. Connection cables
Battery eliminator for mains operation
APU 10 Mini Printer
Neck strap and cradle (hands free use)

¡¡

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ