"Anemometer Calibrations and Aerodynamic Experiments to BS1042"

The Open Jet Wind Tunnel has been developed for the rapid and accurate calibration of anemometers over the range 0.01 to 30 metre/s, and is ideal for organisations such as 'test and calibration establishments' who regularly check anemometers. The equipment also has uses for a variety of small scale aerodynamic experiments where the expense and complexity of an enclosed section wind tunnel would not be justified.

  • The Open Jet Wind Tunnel consists of a single inlet centrifugal fan, driven by 1.5 kW, 3000 rpm (max.), 0-180v D.C. continuously rated, drip-proof, foot-mounted motor controlled by a solid-state, variable speed controller operating on 220/240 volts, single phase, 50/60 Hz supply.
  • The fan feeds air into a 200 mm diameter orifice meter, (to BS1042), fitted with a quick action clamp for changing orifice plates. Four orifice plates are supplied with the equipment, covering the velocity range 0.2 to 30 metres/s.
  • Following the orifice meter is a smoothing chamber containing perforated screens to provide an even flow into a final contraction section. This is terminated with a sharp-edged exit nozzle through which the air is delivered at test velocity. The velocity profile across any traverse is sensibly flat with a sharp cut off at the boundary, providing a free air stream 150 mm (6 in) diameter. The outlet velocity can be periodically checked using a pitot static tube or a calibrated test anemometer (optional).
  • The instrument under test and the check instruments are mounted on a Three-Position rotatable turret with positive locations so that each position can be immediately centralised in the air stream.
  • A 4 mm ellipsoidal nose pitot tube (supplied) is fitted at one station, a master anemometer may be used at another station and the remaining station holds the anemometer under test.

ACCESSORIES

Refer to Anemometer and Electronic/Test Manometer sections for complimentary instrumentation

We suggest the AV6 Anemometer/Logger and MEDM 5K Micromanometer.

¡¡

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ