ÇöÀçÀ§Ä¡ : Home > ÀÌ¿Â ÃøÁ¤±â ¹æ»ç¼±ÃøÁ¤±â UV PROCESS µ¥ÀÌÅͷΰŠ¹× ±â·Ï°è Àü±â ¹× Àü·ÂÃøÁ¤±â ±â»ó°üÃø±â ÃÊÁß°í°úÇб³À°Àåºñ ¾Ð·Â°è ¿È»óÄ«¸Þ¶ó ¿Â¶óÀεβ²ÃøÁ¤±â °æµµ°è Àû¿Ü¼±¿Âµµ°è,¿Âµµ°è ¼ÒÀ½Áøµ¿°è ¿Âµµ/¾Ð·Â/½Àµµ/Àü±â ±³Á¤±â ³ëÁ¡,¿Â½Àµµ,¼öºÐ°è UV°ü·ÃÁ¦Ç° ȸÀü¼öÃøÁ¤±â Lutron1 Á¦Ç° (Àü±â, ÀüÀÚ °èÃø±â) ÀÎÀå¾ÐÃà ÅÙ¼Ç,ÅäÅ© ½ÃÇè±â ÃÊÀ½Æĵβ² ÃøÁ¤±â, Ž»ó±â ÄÚÆõµ±Ý µÎ²²ÃøÁ¤±â dz¼Ódz·®°è À¯·®°è ¿·ù°è, ¿·®°è ±¼Àý°è, Æí±¤°è ÀüÀÚÀú¿ï °¡½ºÃøÁ¤±â ºÐÁø ÀÔÀÚ¼ö ÃøÁ¤±â ¸éÀúÇ× ÃøÁ¤±â »öÂ÷°è, ±¤Åðè Ư¼öÄ«¸Þ¶ó(°í¼Ó °íÇØ»ó) ºÐ±¤±¤µµ°è (Spectrophotometer) ·¹ÀÌÀú Ç¥¸éÁ¶µµ°è Á¤Àü±â, ÀüÀÚÆÄ ÃøÁ¤±â ¿¬¼ÒÈ¿À²ÃøÁ¤±â ¼öÁú½ÃÇè±â ¹°¸®·® ¹°¼º ÃøÁ¤±â ½ë¼ ·¹º§°è (Level) Àü±â°èÃø±â, ÀüÀÚ°èÃø±â Lutron2 Á¦Ç° (¼öÁú,ȸÀü¼ö,¼ÒÀ½Áøµ¿, ±¤·®, ¿Â½Àµµ, dz¼Ó) Testo (¿Âµµ, ½Àµµ, dz¼Ó, ¾Ð·Â, ¼ÒÀ½, RPM, °¡½º) °ø±¸°èÃø±â(Mitutoyo) DAVIS (»óÇ° 25000°³) ºñÆı« ½ÃÇè±â Gardner DNA Fluke Á¦Ç° ¿Âµµ°è Thermometer ºñµð¿À °Ë»ç Çö¹Ì°æ ÀÌÈÇбâ±â ³ó¾÷¿ë ½ÃÇè±â ±¹»ê Á¦ÀÛ±â±â ¹ßÀü±â, ¹èÅ͸® ¹× ÃæÀü±â ÀÇ·á¿ë °èÃø±â ¼Ö¶ó¼¿ (žçÀüÁö), dz·Â, ¼Ò¼ö·Â, ¿¬·áÀüÁö X-Ray °ø±¸°èÃø±â (Fowler) ¿ëÁ¢±â ¹ÝµµÃ¼ Àåºñ À¯¸® ÃøÁ¤±â CRM (°í°´°ü¸®¿ë) ¼ÒÇÁÆ®¿þ¾î ESCO (¿¡½ºÄÚ) µî·Ï Àåºñ ¹«¼±ÃøÁ¤±â ½ÅÁ¾Ç÷ç Àåºñ µ¥ÀÌÅͼöÁý½Ã½ºÅÛ (Data Acquisition) optris(¿ÉÆ®¸®½º) ¹ýÁ¤½ÃÇèÀåºñ (µî·ÏÇã°¡ Àåºñ) ÁÖ¹®»óÇ° Ưº°»óÇ° LED ·¥ÇÁ ¹èÅ͸® 3D Printer Àå±âÀç°í ƯÆÇ (2020³â2¿ù) HOTIK (XINTEST) Á¦Ç° RIGOL Á¦Ç° (Å×½ºÆ®½Ã½ºÅÛ) KEM Á¦Ç° (ºÐ¼®Àåºñ) Ư°¡ÆǸŻóÇ° ±â·ùÃøÁ¤±â ¹× dzµ¿½ÇÇèÀåÄ¡ Ç¥¸é¿°ºÐÃøÁ¤±â ³²ÀÚÀÇ ¹°°Ç(RC) ¿È»óÄ«¸Þ¶ó (Áø´Ü¿ë) MYWATT ½º¸¶Æ® Àü·Â ÃøÁ¤·Î°Å TESTO Àå±âÀç°í (ƯÆÇ) TES Àå±âÀç°í (ƯÆÇ) ÇöÀç ºÐ·ù > ÀÚÀ̷νºÄÚÇÁ Gyroscope, MEMS ·Î°Å¿ë ½ë¼ ÀÚµ¿Â÷¿ë ¼¾¼ ÇöÀç ºÐ·ù > ¿Âµµ¹× ¿·ù ½ë¼ ½Àµµ ½ë¼ ½À±â ½ë¼ ³ëÁ¡ ½ë¼ dz¼Ó ½ë¼ ¾Ð·Â ½ë¼ Èû ½ë¼ º¯À§ ½ë¼ ¼Óµµ ½ë¼ À¯·® ½ë¼ Àü±â ½ë¼ ½Ç³»°øÁ¶ ½ë¼ ±â»ó°üÃø ½ë¼ ±¤º¹»ç ½ë¼ ¼öÁú ½ë¼ °¡½º ½ë¼ ¿ÂµµÁ¶Àý±â ½ë¼ Àû¿Ü¼± ½ë¼ ±³Á¤±â ½ë¼ ÇöÀç ºÐ·ù
FLA603UV22/24 UVA Probe Head Type
High quality probe head for precise determination of UVA radiation in the wave length range from 320 to 400nm.
FLA603UV22/24
UVA Probe Head Type
¡Ü High quality probe
head for precise determination of
UVA radiation in the wave length range from 320 to 400nm.
¡Ü Measurement
geometries with cosine diffusor instead
of simple diffusing screen for highest quality requirements.
¡Ü Three measuring
channels with different sensitivity.
Technical Data:
Measuring range:
FLA603UV22:
0.00002 to 5 mW/cm©÷
FLA603UV24:
0.0004 to 100 mW/cm©÷
Smallest resolution:
FLA603UV22: 10 nW/cm©÷
FLA603UV24: 100 nW/cm©÷
Sensitivity:
approx. 50 nA/(mW/cm©÷)
Spectral sensitivity:
320 to 400nm
Max. cos deviation:
< 5%</font>
Cos diffusor:
diameter 15mm
Nominal temperature:
24¡ÆC ¡¾2K
Operat./storage temperature:
0 to 60¡ÆC/-10 to +80¡ÆC
Humidity range:
10 to 90% (non-condensing)
Dimensions:
¨ª 37mm, height 32mm
Type:
Probe head for
measuring UVA radiation intensity
with ALMEMO¢ç connecting cable 2m long
incl. factory calibration certificate with calibration in mW/cm©÷
FLA603UV22
for examinations in medical therapy
FLA603UV24
for industrial measurements of the UV radiation hardening
»ç¿ëÈı⠸®½ºÆ®
Á¦¸ñ
Æò°¡
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ. Æò°¡Çϱâ
»óÇ°¹®ÀÇ ¸®½ºÆ®
Á¦¸ñ
´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
¹®ÀÇÇϱâ
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.