(ÁÖ)ÄÚ¸°½º

ºÐ·ù °Ë»ö

ÇöÀçÀ§Ä¡ : Home > > >

 
ÀÌÀü Å« À̹ÌÁö ´ÙÀ½

SU135 Current and Voltage Logger

Á¦Á¶»ç : DAVIS
½ÃÁß°¡°Ý : ¿ø
ÆǸŰ¡°Ý  : ¿ø
Æ÷ÀÎÆ® : Á¡
¼ö·® :
  PLUS   MINUS   °³
¡á ȸ¿ø°¡ÀÔÀ» ÇϽøé ÇÒÀεȰ¡°ÝÀ» º¸½Ç¼ö ÀÖ½À´Ï´Ù.
¡á ¸ðµç°¡°ÝÀººÎ°¡¼¼º°µµ ÀÔ´Ï´Ù.
¡á ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á 30¸¸¿ø¹Ì¸¸Àº Åùèºñ 3,000¿ø(ÂøºÒ)ÀÔ´Ï´Ù.
¡á Ä«µå°áÀç½Ã ¼¼±Ý°è»ê¼­ ¹ßÇà ºÒ°¡ÇÕ´Ï´Ù.
¡á ¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.

»ó¼¼ÆäÀÌÁö¸¦ ¸¶ÀÌÇÇÇ÷Πº¸³»±â - À¥¿ë »ó¼¼ÆäÀÌÁö¸¦ twitter·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ facebookÀ¸·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ Me2Day·Î º¸³»±â

FeaturesSU135 Current and Voltage Logger
  • External Current Probe and Voltage Measurements
  • For Simultaneous Current and Voltage Monitoring:
    – Troubleshooting Intermittent Problems
    – Verification of Power Conditions
FeaturesSU136 4-20 ma Loop Measurement
  • Connection for 4 – 20 ma Loop Measurements
  • For Monitoring 4 – 20 ma Process control loops in:
    – Compressor and Fan Run Cycles
    – Manufacturing
    – Package Handling
    – Automated Test Systems
SU137 LOGICiT PC Software and Interface Cable
  • PC Software on CD ROM
  • LINT Interface Cable (From Logger to Serial Port)
SU137 Benefits/Specifications
  • Real Time Monitoring
  • 3 Memory modes: Stop on full, record continuously, or memory rollover
  • Compatible with Windows 95 and above
  • Graphical and Text Data Outputs
  • Exportable Data in Text or Excel Formats
  • Password protected calibration of each channel
  • Minimum System Requirements: 8MB RAM, 2MB Disk Space, 800 x 600 Resolution, COM port or USB port (Optional USB Interface required)
SPECIFICATIONS
  SU135  

SU136

Sample Point Capacity 10,750 points for Current & Voltage

 

21,500 points
  21,500 points for Current OR Voltage

 

¡¡
Alarms Over and under alarms for current and voltage

 

Over and under alarm
Current Range 0 – 300 Amps AC

 

0 – 40 ma input current
Current Accuracy ¡¾ 5%

 

¡¾0. 5%
Current Resolution 0.1 Amp AC

 

0.01 ma
Voltage Range 0 – 500 Volts AC

 

n/a
Voltage Accuracy ¡¾ 1 V AC

 

n/a
Voltage Resolution 0.1 V AC

 

n/a
Time Accuracy  

 

¡¾100ppm @75¡ÆF
Operating Range 
Temperature
32¡ÆF – 140¡ÆF (0¡ÆC – 60¡ÆC) using Alkaline Battery
-40¡ÆF – 150¡ÆF (-40¡ÆC – 65¡ÆC) using Lithium Battery
Humidity
0% to 95%, Non-condensing
Storage Temperature
 -40¡ÆF – 170¡ÆF (-40¡ÆC – 77¡ÆC)
Calibration
Single point offset calibration available through software.Current and Voltage are factory calibrated
Dimensions
3" x 2.5" x 1.1" (7.6cm x 6.4cm x 2.8cm)
Weight
2.5 Oz (71g)
Power Source
9V Alkaline or Lithium Battery
Battery Life (average use)
20 Months using Alkaline Battery 40 Months using Lithium Battery
CAT NO. MODEL DEscRIPTION AVAIL PRICE 
SU135   LCV   Current and Voltage Logger   Yes   310,284
SU136   L420   4-20 ma Process Control Loop Logger   Yes   174,420
SU137   LL5   LOGiT PC Software and Interface Cable   Yes   91,708
SU134   12867   OPTIONAL 300 A Current Probe FOR Current and Voltage Logger 4-20 ma Loop Measurements   Yes   23,868font>

 

SU133   LITH9B   OPTIONAL Lithium Battery FOR Current and Voltage Logger 4-20 ma Loop Measurements   Yes   25,612

 

SU129   USBS   OPTIONAL USB to Serial Interface (USBS) FOR Current and Voltage Logger 4-20 ma Loop Measurements   Yes   18,176