ÇöÀçÀ§Ä¡ : Home > > >
SU138 Temperature and Humidity Logger
|
|
SU139
Pressure and Temperature Logger
|
- External
Pressure and Temperature Measurements
|
| |
|
For
Pressure and Temperature Sensitive Applications
|
- Compressor
Run Cycles
- Testing
New Installations
- Pneumatic
Air Lines
- Tracking
Intermittent Problems
- Superheat
Measurements
|
| |
|
|
SU139
Temperature/ Humidity Logger
|
- Integral
Temperature, Humidity and Dew Point Measurements
|
| |
|
SPECIFICATIONS
| |
SU138
|
SU139
|
| Sample Point
Capacity |
21,500 for
temperature only |
10,750
points for Temp. & Pressure |
| |
10,750 points for
Temperature, Humidity and Dew Point |
21,500
points for Temp. OR Pressure |
| Alarms |
Over and under
alarms for temperature & humidity |
Over
and under alarms for Temp. & Humidity |
| Temperature
Range |
32¡ÆF – 140¡ÆF
(0¡ÆC – 60¡ÆC) w/ Alkaline Battery |
-40¡ÆF
– 150¡ÆF (-40¡ÆC – 65¡ÆC) |
| -40¡ÆF – 150¡ÆF
(-40¡ÆC – 65¡ÆC) w/ Lithium Battery |
|
| Temperature
Accuracy |
¡¾2¡ÆF (1¡ÆC) |
¡¾1¡ÆF
(0.5¡ÆC) |
| Resolution |
0.1¡ÆF (0.05¡ÆC)
|
| Time Accuracy |
¡¾100ppm @75¡ÆF
|
| Relative Humidity
Range |
0% to 99.9%RH,
Non-condensing. |
Pressure
Range: 0 – 500 psi |
| Relative Humidity
Accuracy |
¡¾ 2% full scale,
from 0% to 95% RH for temperatures between 32¡ÆF and 140¡ÆF (0¡ÆC
– 60¡ÆC) |
Pressure
Accuracy ¡¾ 3 psi
Pressure Resolution 0.15 psi |
| Relative Humidity
Resolution |
0.1%RH |
Sensor
SS sensor (6' cable) |
| Operating Range |
32¡ÆF – 130¡ÆF
(0¡ÆC – 54¡ÆC)
|
| Temperature
|
32¡ÆF – 140¡ÆF
(0¡ÆC – 60¡ÆC) using Alkaline Battery
|
|
-40¡ÆF – 150¡ÆF
(-40¡ÆC – 65¡ÆC) using Lithium Battery
|
| Humidity |
0% to 99.9%,
Non-condensing |
0% to
95%, Non-condensing |
| Storage Temperature |
-40¡ÆF – 170¡ÆF
(-40¡ÆC – 77¡ÆC)
|
| Calibration |
Single point offset
calibration available through software
|
| Humidity is factory
calibrated |
Humidity
is factory calibrated |
| Dimensions |
3" x 2.5"
x 1.1" (7.6cm x 6.4cm x 2.8cm)
|
| Weight |
2.5 Oz (71g)
|
| Power Source |
9V Alkaline or
Lithium battery
|
| Battery
Life (average use) |
20 Months using
Alkaline Battery
|
|
40 Months using
Lithium Battery
|
| CAT
NO. |
 |
MODEL |
 |
DEscRIPTION |
 |
AVAIL |
 |
PRICE |
| SU138 |
|
LTH |
|
Temperature
and Humidity Logger |
|
Yes |
|
247,860
|
| SU139 |
|
LPT |
|
Pressure and
Temperature Logger |
|
Yes |
|
413,100
|
| SU133 |
|
LITH9B |
|
OPTIONAL
Lithium Battery FOR
Temperature/Humidity and Pressure/Temperature Logger |
|
Yes |
|
25,612
|
| SU129 |
|
USBS |
|
OPTIONAL
USB to Serial Interface (USBS)
FOR Temperature/Humidity and Pressure/Temperature Logger |
|
Yes |
|
181,794
|
| SU119 |
|
14265 |
|
OPTIONAL
15' Remote Temperature Sensor
FOR Temperature/Humidity and Pressure/Temperature Logger |
|
Yes |
|
34,884
|
| SU140 |
|
12261 |
|
OPTIONAL
Pressure Sensor FOR
Temperature/Humidity and Pressure/Temperature Logger |
|
Yes |
|
174,420
|
| Accessory
Compatible with SU138 |
| SU124 |
|
SW100 |
|
OPTIONAL
Temperature and Probe Extension Wire (100')
FOR Temperature/Humidity and Pressure/Temperature Logger |
|
Yes |
|
73,440
|
| |
»ç¿ëÈı⠸®½ºÆ®
| Á¦¸ñ |
Æò°¡ |
ÀÌ »óǰ¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
* ÀÌ »óǰÀ» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ. Æò°¡Çϱâ
»óǰ¹®ÀÇ ¸®½ºÆ®
| Á¦¸ñ |
´äº¯ |
ÀÌ »óǰ¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº À̰÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
* ÀÌ »óǰ¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
¹®ÀÇÇϱâ
|
|
ÀÌ »óǰ°ú °ü·ÃµÈ »óǰÀÌ ¾ø½À´Ï´Ù. |