ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > Safety ¾ÈÀü¿ë Á¦Ç° > Gas Analyzers

DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
TP707 Single Gas Analyzer
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:TP707
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
Test flue gases in furnaces or combustion equipment and rooms or spaces for the presence
Test flue gases in furnaces or combustion equipment and rooms or spaces for the presence and location of CO leaks. Fits comfortably in your hand, operates with just the push of a button, and comes with a protective rubber boot.
 
Features
  • Fast response and clearing with advanced pump driven technology
  • Peak Hold to capture peak CO reading
  • Instrument will not shut off if 15 ppm CO is present, increasing safety
  • Store Button allows you to save up to eight readings and then print using the IR port and optional A740 printer
  • 1-ppm resolution
  • CO Range 0 to 10,000 ppm
  • Push on fittings are fast and easy to use
  • Large, easy-to-read, backlit display
  • Pump flow block indicator
  • Advanced electrochemical sensor is field replaceable and calibrateable
  • Protective rubber boot and soft carrying case with shoulder strap included
  • Three-year limited warranty on tester and two year limited warranty on CO sensor
 
Applications
  • Test flue gases in furnaces or combustion equipment and rooms or spaces for the presence and location of CO leaks
 
SPECIFICATIONS

Range

0 to 10,000 ppm CO
Resolution 1-ppm
Response time 90% of reading within <60 seconds
Sensor Electromechanical CO sensor/
Two-year limited warranty
Warm Up Approximately 20 seconds
Duty Cycle 30 minutes
Power supply 3 "AA" Alkaline Batteries
Battery Life Approximately 30 hours
Size 3.75 " x 8" x 3" (95 x 203 x 76 mm)
Weight 1.1 lbs (500 g)
Probe length 9 inches (230 mm)
Tube Length 5 feet (152.4 cm)

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
TP707   707   Single Gas Analyzer with protective boot, soft shoulder strap carrying case   Yes   810,000

 

Pump Protective Filter Assembly, In-line Filter Assembly, Flue Probe, three "AA" batteries
TP706   A706   CO replacement sensor   Yes   215,892
TP733   A733   Calibration kit   Yes   475,092
TP728   A728   Calibration gas   Yes   151,092
TP740   A740   IR printer   Yes   431,892
TP762   A762   In-line filter assembly   Yes   64,692
TP729   A729   Flue probe   Yes   129,492
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ