The UE50 and UE75 will enable HVAC professionals to accurately test
The UE50 and UE75 will enable HVAC professionals to accurately test and service all residential combustion appliances. The mutlimeter style rotary selector, allows the technician to easily choose combustion parameters allowing for quick measuring of flue temperature or oxygen and fast calculations of carbon dioxide, gross/net efficiency, or excess air. For technicians who are required to diagnose and repair heating equipment, the UE75 provides the added benefits of measuring Carbon Monoxide and calculating CO air free. Both analyzers have an extra large backlit LCD display that shows two parameters at one time. A protective ruggedize boot with an integral magnet allows for hands-free readings and provides the kind of durability expected.
 
Features
  • Easy multimeter style rotary selector
  • Measures flue temperature and oxygen
  • Calculates carbon dioxide, gross/net efficiency, and excess air
  • Reads pre-programmed fuels natural gas, light oil, propane, butane, & LPG
  • Infrared printer port allows for printing test results to an optional printer with date and time
  • Large back-lit LCD, 2 line display
  • Protected boot with an integral magnet
  • Three year limited warranty with two years on sensor
 
SPECIFICATIONS

Parameter

Resolution Accuracy Range
Flue Temperature 1¡ÆF/¡ÆC ¡¾5¡ÆF (2¡ÆC) ¡¾0.3% reading 32-1112¡ÆF (0-600¡ÆC)
Oxygen 0.1% ¡¾0.2%*1 0-21%
Carbon Monoxide (UE75 Only) 1ppm ¡¾10ppm<100ppm*1 ¡¾5% of reading 0-2000ppm (4000ppm max for 15 mins.)
Carbon Dioxide*2 0.1% ¡¾0.3% reading 0-30%
Efficiency*2 0.1% ¡¾1.0 reading 0-99.9%
Excess Air*2 0.1% ¡¾0.2% 0-250%
Pre-programmed Fuels Natural Gas, Light Oil, Propane, Butane, LPG
Weight 2.2lb (1kg)
Handset 8" (200mm) x 2" (45mm) x 3.5" (90mm)
Probe L 12" (300mm) x Dia 0.25" (6mm) with 8" (200mm) long stainless steel shaft, type K thermocouple and 9ft (3m) long neoprene hose
Ambient Operating Range 32-104¡ÆF (0¡ÆC to 40¡ÆC) 10% to 90% RH non-condensing
Battery Life Standard "AA" (x4) >8 hours continuous use
*1 Using dry gases at STP *2 Calculated

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
UE50   C50   Combustion Analyzer   Yes   861,840
UE75   C75   Combustion Analyzer   Yes   1,079,978
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ