This portable DC dielectric test sets check the electrical insulation quality of motors, power cables, etc.
The Dielectric Test Sets measure leakage current while applying a dc voltage at or above the insulation system¡¯s operating level. This measurement aids in determining the insulation system¡¯s ability to withstand overvoltages such as lightning strikes and switching surges.

This portable DC dielectric test sets check the electrical insulation quality of motors, power cables, switchgear, insulators, transformers and capacitors. Typical applications include acceptance and maintenance testing of critical equipment used by electrical utility substations and industrial plant distribution systems. Power apparatus manufacturers may also use the equipment to perform QA/QC production tests.

The test sets can be used to perform step-voltage and proof tests which, when incorporated into a routine maintenance program, can aid in predicting potential failure before breakdown occurs.
 
Features
  • Continuously variable test voltage
  • Rugged field construction
  • Compact and portable
 
SPECIFICATIONS

Part No.

Model  Test Voltage Range* Max. Power System Voltage Output Current (120-Vac input) Dimensions Weight
BD220005 5 kV 0 to 2.5 kVdc 2.5 kVac 5mA continuous 9.4 H x 13.5 W x 10 D in. 20.5 lb
  0 to 5 kVdc (phase-to-phase)   24.8 H x 34.3 W x 25.4 D cm (9.3 kg)
BD220015 15 kV 0 to 7.5 kVdc 7.5 kVac 5 mA or 12 min; 12 H x 20.5 W x 13 D in. 35.2 lb
  0 to 15 kVdc (phase-to-phase) 2 mA continuous 30.5 H x 52 W x 33 D cm (16 kg)
*Negative polarity with respect to ground
Input 120 Vac, 50/60 Hz
Output
Part No. BD220005
Voltage (maximum) 0 to 5 kVdc, negative with respect to ground
Current (maximum) 5 mA continuous
Metering:Kilovoltmeter 4-in. (102-mm) taut band with two ranges, 0 to 2.5 and 0 to 5 kV
Current Meter 4-in. (102-mm) taut band with four ranges, 0 to 5/50/500 ¥ìA and 5 mA
Part No. BD220015
Voltage  0 to 15 kVdc, negative with respect to ground
Current  2 mA continuous
Short Circuit  12 mA max., limited by circuit breaker
Metering:Kilovoltmeter 4-in. (102-mm) taut band with two ranges, 0 to 7.5 and 0 to 15.0 kV
Current Meter  4-in. (102-mm) taut band with four ranges, 0 to 5/50/500 ¥ìA and 5 mA
Accuracy  ¡¾2% full scale
Temperature Range 0 to 122¡ÆF (-17.7 to +50¡ÆC) operating

CAT NO. MODEL DEscRIPTION AVAIL PRICE
BD220005   220005   DC DIELECTRIC TEST SET 5kV   Yes   4,233,600
BD220015   220015   DC DIELECTRIC TEST SET 15kV   Yes   5,864,400
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ