NP30011 iServer MicroServer¢â
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:NP30011
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
The award-winning NEWPORT¢ç I¢âServer is the simplest, easiest, most economical way
The award-winning NEWPORT¢ç I¢âServer is the simplest, easiest, most economical way to connect serial devices to an Ethernet network and the Internet.
Getting started with the iServer is very simple and easy because it can take a dynamically assigned IP address from a DHCP server on your network. This DHCP client capability is a valuable and unique feature of the NEWPORT iServer that makes it extremely easy and simple to start using this device on almost any Ethernet network.
You can easily assign a static IP address to the iServer instead of a dynamic one, if necessary. The IP address can be assigned locally through its serial connection, as well as remotely over an Ethernet network via Telnet or a web browser, using its factory default IP address.
The NEWPORT iServer connects to an Ethernet Network with a standard RJ45 connector. Serial devices connect to the iServer with a standard DB-9 connector. You can select RS-232, or RS-485 (and RS-422) Serial Communications from the configuration Web page.

The iServer can be used to make an existing Serial device a "node" on an Ethernet network with a unique IP address that's accessible from any authorized computer on the LAN, WAN, or Internet.
The iServer can instead be used to create a virtual tunnel on an Ethernet/Internet network simulating a local point-to-point serial connection between a serial device and a PC. This replaces dedicated point-to-point wiring limited to 50 feet on an RS-232 connection.
The NEWPORT iServer packages the Serial data in standard TCP/IP packets that can travel anywhere on the Ethernet LAN or over the Internet.
The NEWPORT iServer is compatible with almost any device with a Serial interface such as: time clocks, security alarms, card-key access controllers, telecommunications equipment, vending machines, bar code readers, electric power meters, UPS systems, test & measurement instrumentation, PLC's, serial printers, cash registers, and many more.
You do not need to rewrite the firmware for your serial devices to work with the iServer, and in some cases might not need to change your application software. Your serial devices will function over the Ethernet network or the Internet as if they were connected directly to a PC. The COM port on the iServer simulates a local COM port on the PC.
The NEWPORT iServer is compatible with wireless Ethernet. In settings where wires of any kind are not possible, the EIS-W can be connected to a Wireless Ethernet Access Point enabling simple, economical Wireless connectivity of Serial Devices.

 
Features
  • Connect almost any Serial Device to an Ethernet network and the Internet
  • Replace dedicated wiring and PC¡¯s for serial connections
  • Handles RS-232, RS-422 and RS-485 Serial Communications
  • Digital input/output lines
  • Well-developed TCP/IP Stack
  • Web based interface for easy configuration and access without any special software
  • Configuration option via Telnet and Serial
  • DHCP and DNS support for dynamic IP address assignment
  • Password protection for Security
  • Wall mount brackets for secure installation
  • Firmware upgradeable
 
SPECIFICATIONS
Serial Interface
Interface Software selectable RS-232, RS-422 or RS-485 (2 wire)
Connector DB-9 (male DTE)
Data Rates 300 to 115.2 Kbps
Characters 7 or 8 data bits
Parity odd, even, or none
Stop Bits
Flow Control
Digital I/O's
1 or 2
Hardware (RTS/CTS) and Software (Xon/Xoff)
4 digital input/output lines
Network Interface
Interface Ethernet 10Base-T
Connector RJ45
Protocols TCP/IP, ARP, ICMP, DHCP, DNS, HTTP, and Telnet
Indicators (LED's) Power, Network Activity, and Serial Transmit/Receive
Processor
CPU Enhanced 8051, 22 MHz
Memory 512 Kbyte Flash, 16 Kbyte SRAM
Management Embedded Web server, Telnet login, Serial login
Embedded Web Server Serves dynamic Web pages and Java applets (256 Kbyte capacity)
Power
Input 9-12 Vdc (AC adapter included)
Consumption 2 W max.
Environmental
Operating Temperature 0 to 70¡ÆC (32 to 158¡ÆF)
Storage Temperature -40 to 125¡ÆC (-40 to 257¡ÆF)
Packaging
Material Metal case with flange mount
Dimensions 20.8H x 61.6W x 90.3D mm (0.83 x 2.93 x 3.56 in)
Weight 0.18 kg (0.4 lbs.)
Agency Approvals FCC-B, C/UL, CE

CAT NO. MODEL DEscRIPTION AVAIL PRICE
NP30011   EIS-W-70   iServer MicroServer¢â for Serial-to-Ethernet applications 70 VAC, 60 Hz adapter   Yes   421,200

 

The NEWPORT iServer model # EIS-W comes complete with full documentation, firmware, and AC power adapter.
NP30012   EIS-W-240   Server MicroServer¢â for Serial-to-Ethernet applications 240 Vac, 50/60 Hz adapter   Yes   421,200

 

The NEWPORT iServer model # EIS-W comes complete with full documentation, firmware, and AC power adapter.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ