ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > °øÁ¤Á¦¾î process & Control > Transducers/Transmitters

DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ACT3001 Setpoint Controller
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:ACT3001
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
Limit Alarms are setpoint controllers that regulate industrial processes,whether discrete,etc.
Limit Alarms are setpoint controllers that regulate industrial processes, whether discrete, batch or continuous. Alarms are indicators of problems, be they production line faults, process upsets, equipment failures or control system abnormalities.

Alarm Flexibility
The AP1000 Series satisfies the need for compact signal-conditioning equipment that
1) provides the flexibility of a separate, individual limit or on/off control device,
2) accepts a variety of direct sensor or transducer inputs, and 30 provides either Single-Trip, Latching or Dual-trip relay outputs.

The Action Pak 1000 Series provides many combinations of sensor input, setpoint control and relay output selection for most conventional process and industrial alarm/control applications.

Field Configurable Alarms
The popular AP1000 Series Limit Alarms are field configurable. The DC input AP1080/1090, the thermocouple input AP1280/1090 and the AC input AP1690 can all be configured in the field by setting DIP switches for input range or type, alarm function (Hi/Lo) and alarm state (failsafe/non-failsafe). This minimizes spare parts inventory and provides an off the shelf solution for virtually any alarm function.

Lifetime Warranty
All of the Action Pak Limit Alarms carry a lifetime warranty.

 
CAT NO. MODEL DEscRIPTION AVAIL PRICE
ACT3001   AP4380-2000   SETPOINT CONTROLLER, 10MV-100VDC VOLT INPUT   Yes   777,600 
Input Types   DC Volt
Field Configurable Input Span, Min./Max.   10mV to 100mV* span, *Bipolar input switch for +/- 100 Deg.
Mounting Socket   8 pin
Field Configurable Output Type   DC Voltage (0-5V, 0-10V)
ACT3002   AP4390   SETPOINT CONTROLLER, 1MA-100MADC VOLT INPUT   Yes   1,080,000
Input Types   DC Volt
Field Configurable Input Span, Min./Max.   1mA to 100mA*, * Bipolar input switch for +/-100%
Mounting Socket   11 pin
Field Configurable Output Type   DC Current (0-1mA, 4-20mA)
ACT3003   AP4382   SETPOINT CONTROLLER, BIPOLAR INPUT SWITCH   Yes   777,600
Input Types   DC Volt
Field Configurable Input Span, Min./Max.   10mV to 100mV* span, 1mA to 100mA*, * Bipolar input switch for +/-100%
Mounting Socket   8 pin
Field Configurable Output Type   DC Bipolar (-5 to +5V, -10 to +10V)
ACT3004   AP1080   SETPOINT CONTROLLER, 10MV-200VDC CURR INPUT   Yes   486,000
Input Types   DC Current
Field Configurable Input Span, Min./Max.   10mV to 100mV* span, * Bipolar input switch for +/-100%
Mounting Socket   11 pin
Field Configurable Output Type   Alarm (Single DPDT Relay)
ACT3005   AP1090   SETPOINT CONTROLLER, 1-100MA DC CURRENT INPUT   Yes   648,000
Input Types   DC Current
Field Configurable Input Span, Min./Max.   1mA to 100mA*, * Bipolar input switch for +/-100%
Mounting Socket   11 pin
Field Configurable Output Type   Alarm (Dual SPDT Relay)
ACT3012   AP1290   SETPOINT CONTROLLER THERMOCOUPLE INPUT   Yes   691,200
Input Types   Thermocouple
Field Configurable Input Span, Min./Max.   B: 250 to 1320 Deg. C, E: 75 to 1000 Deg. C, J: 63 to 950 Deg. C, K: 63 to 1370 Deg. C, R/S: 100 to 1710 Deg. C, T: 63 to 550 C
Mounting Socket   11 pin
Field Configurable Output Type   Alarm (Dual SPTD Relay)
ACT03   MD03   OPTIONAL TS35 x 7.5 DIN Rail (2 meters) FOR Action Pak¢ç Limit Alarms   Yes   108,000 
MD08   MD08   OPTIONAL DIN-rail mount, 8-pin socket FOR Action Pak¢ç Limit Alarms   Yes   32,400 
MD11   MD11   OPTIONAL DIN-rail mount, 1-pin socket FOR Action Pak¢ç Limit Alarms   Yes   32,400 
IN0 M008   M008   OPTIONAL Surface mount, 8-pin socket FOR Action Pak¢ç Limit Alarms   Yes   32,400 
IN0 M011   M011   OPTIONAL Surface mount, 11-pin socket FOR Action Pak¢ç Limit Alarms   Yes   43,200
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ