ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > Àü±â°èÃø±â Electrical > Àü·ÂÃøÁ¤¿ë ·Î°Å

DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
LM700 Single Phase Color Backlit
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:LM700
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
Photo quality backlit colour display for oscilloscope mode, spectrum mode and multi parameter display
The Power Quality industries¡¯ leading software

Allows the viewer to scroll through event, timeline and waveform data simultaneously, zero in on captured disturbance waveforms, scan historical trends, evaluate static¡¯s and perform harmonic and interharmonic analysis-all with the click of a mouse. With it¡¯s intuitive two-pane browser, complete report writing capabilities, Windows¢ç interface and simple-to-use visualization and analytical capabilities, this software turns every user into a power quality expert.
 
Features
  • Photo quality backlit colour display for oscilloscope mode, spectrum mode and multi parameter display
  • Unique power quality overview mode on a single screen for fast and efficient troubleshooting
  • AC voltage and current (via flexible CT up to 3000A)
  • Additional current probes available for low current measurement
  • mV/A input for installed current transformers
  • W, VA, VAR, kWHr and Power Factor measurement, even for distorted waveforms
  • Built in 3 phase power capability for balanced loads
  • TRMS, Peak, Crest Factor, THD, DF and Frequency for current and voltage
  • Harmonics to the 50th with magnitude and phase information
  • Measurement of dips, sags, swells, flicker
  • Inrush current measurement
  • Record function for MIN, MAX and Average
  • Internal datalogging and full power quality surveying with time and date stamped values
  • Reporting to EN50160 power quality standard with customized parameters
 
SPECIFICATIONS
Nominal Voltage Delta: 200/400/830V
Star: 115/230/480V
Intrinsic Error 115V - 830V – 0.2%; Resolution 0.1V
Current Ranges 30/300/3000A ; Intrinsic Error 0.5% (excludes probe); Resolution 0.01A
Power Intrinsic Error 1%; Resolution 1W
Frequency Range 45-65Hz; Intrinsic Error 0.2%; Resolution 0.01Hz
Harmonics 1st-50th Vrms, Irms, THD V, THD I
Events ntrinsic Error 1%; Flicker FL, Pst, Plt, IEC 1000-4-15; Intrinsic Error 3%

CAT NO. MODEL DEscRIPTION AVAIL PRICE
LM700   Analyst Q70   Single Phase Color Backlit Graphical Power Quality Instrument   Yes   4,571,640
1, 30/300/3000A LEMflex flexible CT, Dran-View¢ç software, carrying case
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.

DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ