¡Ü Probe
tube with heated miniature thermistor for flow
measurement and precision NTC resistance for measuring the ambient temperature
and automatic compensation.
¡Ü Evaluation
electronics are located in a separate sensor transmitter module.
¡Ü High
accuracy as a result of integrated temperature
compensation and individual calibration in wind tunnel, with laser Doppler
anemometer as reference system.
¡Ü Response
time only 2s for smoothing the measured value indicated, optionally without
smoothing with 100ms response time.
¡Ü Suitable
for measuring small flow velocities in gaseous substances, particularly
for control systems and monitoring.
¡Ü Typical
applications include comfort index measurements, HEVAC applications, environmental
technology, clean room technology and process measuring and control technology.
¢Æ A special connector cable allows to connect the flow
sensors to all ALMEMO¢ç multi-purpose devices, data
loggers and data acquisition systems. For volume flow
rate measurements the cross section of the ventilating
shaft can be easily entered into ALMEMO¢ç devices. A
problem-free averaging is then possible.
Types (incl. clamping holder
and ALMEMO¢ç connecting cable 1.5m long): |
Unidirectional (sensitive in one direction)
with protected measuring tip |
FVA605TA1 |
Measuring range 0 to 1m/s |
FVA605TA5 |
Measuring range 0 to 5m/s |
Omnidirectional (direction-independent,
symmetrical ball tip) with protecting cage (¨ª110mm) including carry-case |
FVA605TA1O |
Measuring range 0 to 1m/s |
FVA605TA5O |
Measuring range 0 to 5m/s |
|
Technical Data: |
Electronics Box with Sensor |
Measuring range:
FV A605 TA1(O)
FV A605 TA5(O) |
0.01 to 1m/s
0.15 to 5m/s |
Resolution:
FV A605 TA1(O)
FV A605 TA5(O) |
0.001m/s
0.01m/s |
Accuracy:
FV A605 TA1(O)
FV A605 TA5(O) |
¡¾1.0% of final value and
¡¾1.5% of meas. value
¡¾0.5% of final value
¡¾1.5% of meas. value |
Nominal conditions: |
22¡ÆC, 960hPa |
Automatic
temperature compensation: |
effective in range 0 to 40¡Æ |
Temperature influence: |
¡¾0.5% of fin. value/¡ÆC |
Sensor |
Head size: |
¨ª 8mm |
Shaft: |
¨ª 15mm |
Operative range: |
0 to 40¡ÆC |
Angle of attack:
FV A605 TA1/TA5
FV A605 TA1O/TA5O |
¡¾30¡Æ
¡¾180¡Æ |
Inlet opening:
FV A605 TAx:
FV A605 TAxO: |
9mm
protecting cage |
Sensor length:
FV A605 TAx:
FV A605 TAxO |
300m
310mm |
Sensor cable length: |
1.5m |
Storage temperature: |
-30 to +90¡ÆC |
General Technical Specifications |
Measurement medium: |
dry air or inert |
Response time: |
standard:
smoothened: 1 ¥ó = 2s
option OAA605TAU:
not smoothened: 1 ¥ó = 100ms |
Power supply: |
through ALMEMO¢ç device
(approx. 7¡¦ 10V) |
Current consumption: |
approx. 70mA |
Output signal: |
0 ¡¦ 1V, linearised,
load resistance min. 10kohms |
Housing:
Dimensions:
Protection system:
Weight:
|
100 x 60 x 35mm (L x W x H)
IP 40 (aluminium housing)
approx. 250g |
Operating temperature: |
0 to 40 |
Storage temperature: |
-30 to 90¡ÆC |
Air humidity: |
0 ¡¦ 90% r.H., non-condensing |
Adjusting reference: |
laser Doppler wind tunnel,
adjustment at 22¡ÆC/approx.
960hPa, (certificate according
to SN EN 45001) |
|