Compact pressure sensors for industrial applications in liquid and gaseous substances.
FDA602L Pressure Transducer Type

¡Ü Compact pressure sensors for industrial applications
in liquid and gaseous substances.
¡Ü Piezo-resistive, flexibly suspended silicone measuring cell in an oil-filled, all-welded special steel enclosure.
¡Ü The stable mechanical construction provides a reliable
protection for the measuring cell against the test
substance and immunes it against pressure peaks and vibrations.
¡Ü Available with three calibrations.
Relative pressure: pressure related to the environmental press.
Absolute pressure: pressure related to vacuum (0 bar)
Overpressure: pressure related to atm. pressure at
manufacturing (approx. 1bar).

Accessories:
ZB9060K(L)  Longer cable, please specify length (L)

Types:
including ALMEMO¢ç cable 1.5m long 
Measuring ranges relative pressure:
FDA602L3R up to 2.5 bar
FDA602L5R up to 10 bar
Measuring ranges absolute pressure:
FDA602L4A up to 5 bar
FDA602L5A up to 10 bar
Measuring ranges excess pressure:
FDA602L2U up to 25 bar
FDA602L3U up to 50 bar
FDA602L4U up to 100 bar
Technical Data:
Overload : 1.3 times the final value
Output signal: 0.2 ¡¦ 2.2V
Response time: < 2ms
Category of accuracy:            ¡¾1% of final value
 (linearity + hysteresis + reproducibility)
Linearity: 0.5% max.
Total error range*:
+18 ¡¦ +22¡ÆC:                           1% max. / 0.5% typ.
0 ¡¦ +18 / +22 ¡¦ +50¡ÆC:           2% max. / 1% typ.
-20 ¡¦ 0 / +50 ¡¦ +80¡ÆC:
           4% max. / 2.5% typ.
* including linearity, hysteresis, zero point and sensitivity,
temperature effects, reproducibility
 
Nominal conditions: 22¡ÆC ¡¾ 2K, 10 to 90% rH
non-condensing
Power supply: 6 to 15VDC, <4 mA
Housing: <25 bar: special steel 1.4301
>25 bar: special steel 1.4571
Pressure sensor membrane: special steel 1.4435
Operating temperature: -20 to +80¡ÆC
Fitting: ext. thread G1/4¡±, membrane
not flush with front
Pressure medium: compatible with stainless steel
Weight: 75g
Electromagn. compatibility: CE marked: test acc. to IEC
801.2 and 802.2
Protection system: IP 65
Insulation: > 100M§Ù / 50VDC
Insulation test: 1 minute at 500VDC

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ