JF150310 Portable Signal Calibrator Electrical
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:JF150310
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
The TRX allows for fast and easy operation with its user-friendly design. By scrolling through the menu, the display will prompt the operator through calibrations by asking questions such as : Select ¡°INPUT or OUTPUT,¡± select MILLIAMPS, MILLIVOLTS, T/C¡±, etc. Settings can be changed at any time by pressing the ¡°C/CE¡± key which allows you to step backwards in the program and after previous settings.

The programmable step function allows for storage of up to six calibration values. These values can be recalled manually in sequence or be sent out automatically over a preprogrammed time interval. The ¡°FIXED STEPS¡± key allows for output of signals in 0%, 25%, 50%, 75% and 100% of selected span value.

The TRX offers a wide choice of measuring, simulation and combination possibilities including: Steps, Ramping, Temp Xmtr Calibration, Scaling, Selectable Standards, Cold Junction Compensation, Loop Testing, Speed Setting, etc.

The TRX will allow you to measure and simulate millivolts, Volts, Ohms, RTD¡¯s, Thermocouples, Milliamps, and also provide a 24 VDC power supply for 2/3 wire 4-20 mA or 0-20 mA transmitters.

The TRX is the ideal tool for the instrument engineer as it can act as a simulator, receiving controller, power supply and decade box to make maintenance, checking and calibration of many devices including RTD¡¯s and T/C¡¯s very easy.
Features
  • All in one instrument
  • Cold junction compensated
  • Measures signals
  • Simulates signals
  • Rugged filed instrument
  • Compact size
  • Self testing
  • Programmable
  • Ramp functions
  • Complete XMTR calibration
  • Step functions
  • mA scaling
  • IEC/ANSI-DIN-JIS curves
  • Optional: NIST traceable certificate
  • Instrinsically safe model available
SPECIFICATIONS

Reference

20¡ÆC (68¡ÆF)¡¾3K
Long Term Drift ¡¾0.03% of range/year
Indicated Accuracies Specified for 15¡ÆC (60¡ÆF) to 35¡ÆC (95¡ÆF).
Outside these limits: ¡¾1 digit on zero and ¡¾0.005% (0.0025%) of range/¡ÆC(¡ÆF)
Operating Temperature -10¡ÆC to +50¡ÆC (14¡ÆF to 122¡ÆF)
Storage Temperature -20¡ÆC to +70¡ÆC (-4¡ÆF to 158¡ÆF)
Calibration Traceable to National Standards with correlation to NBS
Warm Up Time 2 minutes in a constant ambient temperature
Relative Humidity 0 to 90% non-condensing
Cold Junction Compensation ¡¾0.25¡ÆC (0.5¡ÆF) with the Pt100 sensor in the connection module or 0.8¡ÆC (1.4¡ÆF) with the semi-conductor sensor in model MLC housing or to be set by the user with 99¡ÆC/¡ÆF to 99¡ÆC/¡ÆF
Excitation Current, RTD Simulation 5mA max,either polarity (from an external source)
Read-out 41/2 or 4 digits, depending on the selected function, Text in English
Batteries 4 x 1.5 Volt, type LR14 or size C
Battery Life 25 hours with alkaline batteries at 20¡ÆC (68¡ÆF), 12 hours with 20 mA load
Low Battery Indication Pre-warning alternately flashes "poor battery" after approx. 15 minutes the unit stops and indicates steady "replace batteries"
External Power Supply 2.5mm plug, 6 Volt at 300mA
Connections Suitable for 2mm banana plugs or loose wire end (with connection module)
Protection IP53
Housing Textured high-impact ABS plastic
Hazardous Area Designed for use in div. 2 classified areas
Size 200 x 117 x 32mm (8.0 x 4.7 x 1.3") without carrying case
Weight 0.7kg (1.65 pound) including batteries and carrying case

SPECIFICATIONS

Function

Range Range Resolution Accuracy Remarks
Measure mVolt 0-120mV 0.01mV ¡¾0.025% R-input>20M¥Ø
Output mVolt -10-120mV 0.01mV ¡¾0.025% R-output 0,2¥Ø
Measure Volt 0-120V 0.01V ¡¾0.05% R-input>1M¥Ø
Output Volt 0-12V 0.001V ¡¾0.025% R-output 0.2¥Ø
Measure mA 0-52mA 0.01mA ¡¾0.05% R-input 10¥Ø
Output mA 0-24mA 0.01mA ¡¾0.05% R-max. 900¥Ø
Transmitter Sim. 0-24mA 0.01mA ¡¾0.05% V-max ext. 56 volts
Meas./Sim. Ohm 0-390¥Ø 0.1¥Ø ¡¾0.1¥Ø

For RTD's and
Ohms
¡¾0.25¡ÆC/0.5¡ÆF
1.25mA excitation
current, Curves IEC
751 (385) or JIS
(392)

Thermocouples
J,K,T,B,R,S and E
in accordance with
IEC standard 584-1
or DIN 43710 for
U and L

Meas./Sim. Pt100 -200/850¡ÆC -328/1562¡ÆF 0.25¡ÆC/0.5¡ÆF ¡¾0.25¡ÆC/0.5¡ÆF
Meas./Sim. Nl100 -60/850¡ÆC -76/482¡ÆF 0.25¡ÆC/0.5¡ÆF ¡¾0.25¡ÆC/0.5¡ÆF
Meas./Sim. TC-J/L -210/1190¡ÆC -346/2174¡ÆF 0.2¡ÆC/0.4¡ÆF ¡¾0.4¡ÆC/0.8¡ÆF
Meas./Sim. TC-K -210/1370¡ÆC -346/2498¡ÆF 0.2¡ÆC/0.4¡ÆF ¡¾0.6¡ÆC/1.2¡ÆF
Meas./Sim. TC-K -230/-210¡ÆC -382/-346¡ÆF 1¡ÆC/2¡ÆF ¡¾2¡ÆC/4¡ÆF
Meas./Sim. TC-T/U -75/400¡ÆC -103/752¡ÆF 0.2¡ÆC/0.4¡ÆF ¡¾0.5¡ÆC/1¡ÆF
Meas./Sim. TC-T/U -180/-75¡ÆC -292/-103¡ÆF 0.4¡ÆC/0.8¡ÆF ¡¾1¡ÆC/2¡ÆF
Meas./Sim. TC-T/U -250/-180¡ÆC -418/-292¡ÆF 0.6¡ÆC/1.2¡ÆF ¡¾1.6¡ÆC/3.2¡ÆF
Meas./Sim.TC-B 540/1810¡ÆC 1004/3290¡ÆC 1¡ÆC/2¡ÆF ¡¾2.5¡ÆC/5¡ÆF
Meas./Sim. TC-B 315/540¡ÆC 599/1004¡ÆF 2¡ÆC/4¡ÆF ¡¾6¡ÆC/12¡ÆF
Meas./Sim. TC-B 180/315¡ÆC 356/599¡ÆF 4¡ÆC/7¡ÆF ¡¾8¡ÆC/16¡ÆF
Meas./Sim TC-R -50/1760¡ÆC -58/3200¡ÆF 0.7¡ÆC/1.4¡ÆF ¡¾2¡ÆC/4¡ÆF
Meas./Sim. TC-S -50/1760¡ÆC -58/3200¡ÆF 0.8¡ÆC/1.6¡ÆF ¡¾2¡ÆC/4¡ÆF
Meas./Sim. TC-E -240/1000¡ÆC -400/1832¡ÆF 0.1¡ÆC/0.2¡ÆF ¡¾0.3¡ÆC/0.6¡ÆF
Meas./Sim TC-E -250/-240¡ÆC -418/-400¡ÆF 0.8¡ÆC/1.6¡ÆF ¡¾2¡ÆC/4¡ÆF
Meas./Sim TC-N 0/1300¡ÆC 32/2372¡ÆF 0.2¡ÆC/0.4¡ÆF ¡¾0.6¡ÆC/1.2¡ÆF
Notes: Indicated ranges for thermocouples are in accordance with IEC 584-1 Menu selectable curves. IEC/ANSI DIN or JIS

CAT NO. MODEL DEscRIPTION AVAIL PRICE
JF150310 TRX Portable Signal Calibrator Yes 3,662,820
With carrying case, set of batteries, instruction guide spare fuse, terminal block and test leads
UM13603 191-A005 OPTIONAL Power Supply, 70V FOR Portable Signal Calibrator Yes 201,960

UM050 191-A006 OPTIONAL Terminal Block FOR Portable Signal Calibrator Yes 358,020
UM500 191-A014 OPTIONAL Extension Cable Kit FOR Portable Signal Calibrator Yes 275,400

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ