Features |
- Sources and reads millivolts, volts and milliamps
- Powers, reads and simulates 2-wire transmitters
- Simultaneous input and output readings
- Fixed calibration steps
- Automatic signal ramping
|
| |
|
Calibrator includes |
- Carrying case
- Batteries
- Instruction manual
- NIST Certification available
- Spare fuse
- Set of test leads
|
| | SPECIFICATIONS
Function |
Range |
Resolution |
Accuracy % of reading |
Remarks |
Measure mVolts |
0-120mV |
0.01 mV |
¡¾0.017% ¡¾1 digit |
R-input ¡Ã20 M¨¡ |
Output mVolts |
0-120mV |
0.01mV |
¡¾0.017% ¡¾1 digit |
R-output 0,2¨¡ |
Measure Volts |
0-120V |
0.01V |
¡¾0.04% ¡¾1 digit |
R-input 1 M¨¡ |
Output Volts |
0-12V |
0.001V |
¡¾0.017% ¡¾1 digit |
R-output 0,2 ¨¡ |
Measure mA |
0-52mA |
0.01mA |
¡¾0.04% ¡¾1 digit |
R-input 3,5 ¨¡ fused |
Output mA |
0-24mA |
0.01mA |
¡¾0.04% ¡¾1 digit |
R-max. 900 ¨¡ |
Transmitter Sim. |
0-24mA |
0.01mA |
¡¾0.04% ¡¾1 digit |
V-max ext. 56 Volts |
Special Functions |
1. Fixed steps (programmable, 10% or 20% divisions) |
2. Signal ramping (up/dwell/down)Reference 22¡ÆC ¡¾1 |
Calibration |
Traceable to National Standards with correlation to NIST |
Long Term Stability |
0.02%/year of span |
Indicated Accuracies |
Specified for 15¡ÆC to 35¡ÆC. Outside these limits; ¡¾ 1/sd max. on zero and ¡¾0.001%/¡ÆC of span |
Operating Temperature |
-10¡ÆC to +50¡ÆC (14¡ÆF to 122¡ÆF) |
Storage Temperature |
-20¡ÆC to +70¡ÆC (-4¡ÆF to 158¡ÆF) |
Warm up Time |
2 minutes to rated accuracy |
Relative Humidity |
0 to 90% non-condensing |
Input/output Protection |
70 volts on millivolt input, 30Volts on Volts input |
Input/output Isolation |
500VDC continuous |
Output Voltage |
Protected by load monitor, displays "check loop" |
Output Current |
Protected by load monitor, display "check loop" |
Transmitter Power Supply |
Available for user; 24VDC current limited at 34mA |
Read-out |
Simultaneous read-out of input and output values. Dialogue in english |
Batteries |
4 x 1.5Volt, type R14 (Size C alkaline) or rechargeable NiCad |
Battery Life |
22 hours with alkaline batteries at 20¡ÆC (68¡ÆF), 7 hours with 20mA load |
Low-battery Indication |
Pre-warning alternately flashes "bat" |
External Power Supply |
By optional charge/line adapter p/n 13603 230/115V—50/60 Hz |
Connections |
Suitable for 4mm test plugs |
Protection |
IP 53 |
Housing |
Textured high-impact ABS plastic |
Size |
200 x 117 x 32mm (8.0" x 4.7" x 1.3") without carrying case |
Weight |
0.9 kg ( 2 pounds) including batteries, carrying case and test leads |
CAT NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
UM68900 |
|
MVX |
|
MULTI-CALIBRATOR FOR PROCESS SIGNALS (mV,V,mA) |
|
Yes |
|
2,383,128 |
UM13603 |
|
191-A005 |
|
OPTIONAL Power Supply, 110V FOR Process Signal Multi-Calibrator |
|
Yes |
|
201,960
|
UM063 |
|
191-A010 |
|
OPTIONAL SET OF TEST LEADS FOR MVX FOR Process Signal Multi-Calibrator |
|
Yes |
|
73,440
| | |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
|
|
|
ȸ»ç¼Ò°³ | ¼ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ |
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
|
|
|
|