HR9132 Portable IR Calibrator, 500¡ÆC
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
Whether your using in-line or handheld infrared pyrometers, you need good calibration standard to verify their accuracy. Our new portable IR calibrators provide stable blackbody targets for calibrating noncontact IR thermometers from -30¡ÆC to 500¡ÆC. These new units feature a large, temperature controlled black-body target with a diameter of 2.25" (57mm), which offers large field of view area for optical variations in infrared thermometers. The emissivity of the isothermal target is set at 0.95, and the target temperature can be controlled in set-point increments of 0.1¡Æ from -30¡ÆC to 500¡ÆC.

For even higher precision, a well is located directly behind the blackbody surface for contact calibration of the blackbody. Using an optional calibrated PRT and readout device, target accuracy of ¡¾0.075¡ÆC can be achieved.

These units are easy to use as "point and shoot." Simply set the desired blackbody temperature from the convenient front panel control buttons, wait a few minutes for equilibrium, and point the gun at the target. The radiated energy from the blackbody is measured by your IR thermometer. Simply compare its reading to the display on the blackbody and record the difference.

9132 For IR calibrations above normal ambient, the 9132 provides a stable blackbody target up to 500¡ÆC (932¡ÆF). With accuracy to ¡¾0.5¡ÆC and stability to ¡¾0.1¡ÆC, this new portable IR unit can certify most handheld pyrometers.

Short heating and cooling times mean you won't have to wait long to get your work done. From room temperature to 500¡ÆC the 9132 will be stable within 30 minutes. You won't find a more compact IR calibrator.

9133 If you're calibrating IR guns are at cold temperatures, you'll love our new 9133. With solid state cooling technology, this new IR calibrator reaches -30¡ÆC (-22¡ÆF) in normal ambient conditions. With a new conveniently located dry gas fitting on the front bezel, the 9133 won't build up ice on the target. At the upper end of its range, the 9133 provides stable temperature to 150¡ÆC (302¡ÆF).

With heating and cooling times of about 15 minutes from ambient to either extreme, the 9133 gets you to temperature quickly and performs when it gets there. Compare your IR devices to the temperature display - its factory calibrated (NIST traceable) to be within ¡¾0.4¡ÆC (¡¾0.7¡ÆF). No other IR calibrator gives you this level of precision in such a compact package. Whatever your temperature application, trust a Hart product to solve it.

 
Features
  • Certify IR pyrometers from –30¡ÆC to 500¡ÆC (–22¡ÆF to 932¡ÆF)
  • Large 2.25" (57mm) blackbody target
  • RTD refence well for high precision
  • Small, compact design
 

SPECIFICATIONS

HR9132

HR9133

Temperature Range

50¡ÆC to 500¡ÆC

–30¡ÆC to 150¡ÆC at 23¡ÆC ambient

(122¡ÆF to 932¡ÆF)

(–22¡ÆF to 302¡ÆF at 73¡ÆF ambient)

Accuracy

¡¾0.5¡ÆC at 100¡ÆC (0.9¡ÆF at 212¡ÆF)

¡¾0.4¡ÆC (¡¾0.72¡ÆF)

¡¾0.8¡ÆC at 500¡ÆC (¡¾1.4¡ÆF at 932¡ÆF)

 
Stability 

¡¾0.1¡ÆC at 100¡ÆC (¡¾0.18¡Æf at 212¡ÆF)

¡¾0.1¡ÆC (¡¾0.18¡ÆF)

¡¾0.3¡ÆC at 500¡ÆC (¡¾0.54¡ÆF at 932¡ÆF)

 
Target Size

2.25" (57mm)

Target Emissivity

0.95 ¡¾0.02 from 8 to 14¥ìm

Resolution

0.1¡Æ

Heating Time

30 minutes (50¡ÆC to 500¡ÆC)

15 minutes (25¡ÆC to 150¡ÆC)

Cooling Time

30 minutes (500¡ÆC to 100¡ÆC)

15 minutes (25¡ÆC to –20¡ÆC)

Computer Interface

RS-232 included with 9930 interface-it software

Power

115VAC (¡¾10%), 3 A or 230 VAC (¡¾10%), 1.5 A, switchable, 50/60 Hz

115 VAC(¡¾10%), 1.5 A, 230 VAC (¡¾10%), 1.0A, switchable, 50/60 Hz

Size

4" H x 6" W x 7 " D

6" H x 11.25" W x 10.5' D

 

(102 x 152 x 178 mm)

(152 x 268 x 267 mm)

Weight

4 lb. (1.8 kg)

10 lb. (4.6 kg)


CAT NO. MODEL DEscRIPTION AVAIL PRICE 
HR9132   9132   Portable IR Calibrator, 500¡ÆC   Yes   4,718,520
HR9308   9308   RUGGED CARRYING CASE   Yes   128,520 
HR9133   9133   Portable IR Calibrator, -30¡ÆC   Yes   6,811,560
HR9302   9302   Rugged Carrying Case, (Holds base unit and up to five modules)   Yes   541,620

 

HR1700   1700   OPTIONAL HAND HELD THERMOMETER FOR Portable IR Calibrators   Yes   1,881,900

 

HR56189   5618-9   OPTIONAL Secondary Reference PRT, 1/8" diameter, -200¡ÆC to 500¡ÆC FOR Portable IR Calibrators   Yes   1,092,420

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ