ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > ±³Á¤±â Calibrators > ¿Âµµ Temperature
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
TT60100 High Temperature Black-Body Calibrator
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
The Gemini R is a blackbody source with which radiation pyrometers, commonly referred to as IR sensors, can be calibrated. With a temperature range of 50¨¬C to 550¨¬C, the temperature of the cavity can be set with 0.1¨¬C resolution. The temperature of the furnace is set and indicated on a PID controller. An independent indicator is also provided for higher accuracy with a standard probe, which indicates the actual radiance temperature. Temperature variation over a 5-minute period, as viewed on the temperature controller, is ¡¾0.2¨¬C and a radiation thermometer directed into the cavity detects similar variations.

The Gemini R¡¯s cavity¡¯s size is 2.5" ¨ª x 6.3" deep (65mm x 160mm). Maximum temperature differences are ¡¾1¨¬C in the range of 100¨¬C to 500¨¬C. The Gemini R is capable of accepting blackbody fixed points to achieve the highest level of a radiation measurement possible. Typical fixed-point uncertainties are ¡¾0.25¨¬C. Gallium, indium, tin and zinc cells are available.

Emissivity is greater than 0.995, and traceability may be established with a NIST certificate for the built-in indicator and/or supplied probe. The Gemini R can be supplied with RS232 or RS422 communications.

A compact furnace for calibrating radiation pyrometers, the Pegasus R sets the temperature of the furnace on a controller while an independent indicator, whose sensor is built into the furnace¡¯s cavity, indicates the actual radiance temperature. The cavity¡¯s diameter is 0.8" (20mm). The depth is 2.6" (65mm). The emissivity is 0.995. The cavity is removable and a fixed-point cell may be put in its place.

A Blackbody Target Radiation Source is housed within the Pegasus R for the calibration of radiation thermometers in the wavelength range of 9 to 14 micrometers. Incorporating suitable insulation within its design, this radiation source¡¯s aperture is 0.4" (10mm) in diameter. A scan across the aperture at 444¨¬C demonstrates the source is uniform to better than 0.3¨¬C. Traceability may be established with a NIST certificate for the built-in indicator and supplied probe.

The Pegasus R¡¯s temperature range is 150¨¬C to 1200¨¬C and it has a stability of 0.1¨¬C. Time to temperature is 20 minutes. It weighs only 15 lb. and is easily carried in the field for on-site use. The Pegasus R can be supplied with either RS232 or RS422 communications.

 
Features
  • Medium & High Temperature Radiation Pyrometer Primary Source
  • 0.995 Emissivity
  • Accepts Fixed Point Cells
  • NIST Certificate for the built-in Indicator and supplied probe
 
SPECIFICATIONS

Model

GR PR
Temperature Range 50 to 550¡ÆC (122 to 1022¡ÆF) 150 to 1200¡ÆC (302 to 2192¡ÆF)
Emissivity Greater than 0.995 0.995
Stability ¡¾0.1¡ÆC ¡¾0.1¡ÆC (¡¾.18¡ÆF)
Display Resolution 0.1¡ÆC 1¡ÆC
Cavity Size 2.5" ¨ª x 6.3" deep (65mm ¨ª x 160mm) .8" ¨ª x 2.6" deep (20mm ¨ª x 65mm)
Time to Temperature 45 minutes 20 minutes
Power 1000 watts typical, 100-130 or 208-240V AC, 50/60Hz 2.3kW typical, 100-130 or 208-240V AC, 50/60Hz
Dimensions 12.2" x 10.4" x 7.9" 12.3" x 10.5" x 8"
Weight 22 lb. 15 lb.

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
TT60100   Pegasus-R   High Temperature Black-Body Calibrator including standard probe   Yes   14,412,600

 

TT60101   Gemini-R   Radiation Calibrator including standard probe   Yes   10,208,160

 

TT60102   Gemini-R-INS-FG   OPTIONAL Gallium Hockey Puck Cell FOR Infrared Thermometer Calibrators   Yes   4,590,000

 

TT60103   Gemini-R-INS-FI   OPTIONAL Indium Hockey Puck Cell FOR Infrared Thermometer Calibrators   Yes   4,590,000

 

TT60104   Gemini-R-INS-FZ   OPTIONAL Zinc Hockey Puck Cell FOR Infrared Thermometer Calibrators   Yes   4,590,000

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ