Precision infrared temperature measurement has been used for years to increase productivity, reduce costs and improve product quality. Microfabrication techniques have allowed us to reduce the size and cost of our sensors--bringing the benefits of this technology to a new group of users. The Thermalert MID is designed for applications in the -40 to 600¡ÆC (-40 to 1112¡ÆF) temperature range.

World¡¯s smallest IR sensors
The Thermalert MID is a two-piece system with miniature sensing head and separate electronics. The sensor is small enough to be installed just about anywhere, yet it performs as well as much larger systems. The sensor is housed in rugged stainless steel to ensure long-term performance even in harsh environments with ambient temperatures up to 85¡ÆC (185¡ÆF). And the MID¡¯s response time is as fast or faster than many high-end systems.

Rugged, reliable, practical features
The MID¡¯s electronics include: Emissivity Adjustment and selectable Peak Hold, Valley Hold and Averaging features you won¡¯t normally find in systems in this price range. Output format is field selectable. Accessories, including an air purge jacket, air cooling jacket, and mounting adapters, ensure accuracy in applications ranging from plastics manufacturing to food processing.

We¡¯ve made IR affordable
The MID¡¯s miniature size and low cost make it ideal for installation at multiple points along your process. Accurate, easy to install and practical.

 
Models MID02 and MID10
  • Field selectable J or K thermocouples, 4-20mA, 0-20mA or 0-5V
  • Temperature range: -40 to 1112¡ÆF (-40 to 600¡ÆC)
 
Accuracy
  • 1% of reading or ¡¾1¡ÆC, whichever is greater @ 23¡ÆC ¡¾ 5¡ÆC (73¡ÆF ¡¾ 9¡ÆF)
  • Thermocouple output accuracy ¡¾1% if reading or ¡¾2.5¡ÆC, whichever is greater @ 23¡ÆC ¡¾5¡ÆC
 
SPECIFICATIONS

Temperature Range

-40 to 600¡ÆC (-40 to 1112¡ÆF)
-25 to 600¡ÆC for J Thermocouple output
Repeatablility ¡¾0.5% of reading or ¡¾0.5¡ÆC (1¡ÆF),
whichever is greater
Temperature resolution 0.3ûC (0.5ûF)
Response time 150 mSec (95% response)
Resolution (optical) 2:1, 10:1
Spectral Response 8-14 microns
Emissivity 0.100 to 1.100 digitally adjustable increments of .001
Signal Processing Peak/Valley Hold, Variable Averaging Filter, adjustable up to 998 seconds
MECHANICAL
Sensing head construction Stainless steel
Dimensions  14 mm dia x 28 mm L (0.55 in dia x 1.1 in L)
Weight with 1 m cable 50 g (1.75 oz)
Electronics housing with electronics card construction zinc, die-cast
Dimensions 80 x 60 x 25 mm (3.2 x 2.4 x 1.0 in)
Weight 270 g (9.5 oz)
Cable length 1 m (3 ft)

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
RY4449130   MID02LT   Non-contact temperature sensor 2:1 optics, 1m (3.3 ft) cable   Yes   504,900
RY4449139   MID02LTCB3   Non-contact temperature sensor 2:1 optics, 3m (9.8 ft) cable   Yes   541,620
RY4449129   MID02LTCB8   Non-contact temperature sensor 2:1 optics, 8m (26 ft) cable   Yes   605,880
RY4449140   MID02LTCB15   Non-contact temperature sensor 2:1 optics, 15m (49 ft) cable   Yes   670,140
RY4449128   MID10LT   Non-contact temperature sensor 10:1 optics, 1m (3.3 ft) cable   Yes   642,600
RY4449143   MID10LTCCB3   Non-contact temperature sensor 10:1 optics, 3m (9.8 ft) cable   Yes   679,320
RY4449124   MID10LTCB8   Non-contact temperature sensor 10:1 optics, 8m (26 ft) cable   Yes   743,580
RY4449144   MID10LTCB15   Non-contact temperature sensor 10:1 optics, 15m (49 ft) cable   Yes   807,840
RY449105   MIACFB   OPTIONAL Fixed mounting bracket FOR Miniature Non-Contact Temperature Sensor   Yes   36,720

 

RY449106   MIACAB   OPTIONAL Adjustable mounting bracket FOR Miniature Non-Contact Temperature Sensor   Yes   64,260

 

RY449107   MIACAJ   OPTIONAL Air purge jacket FOR Miniature Non-Contact Temperature Sensor   Yes   91,800

 

RY449109   MIACCJ   OPTIONAL Air cooling/purging system with 2.8m (9.2") air hose FOR Miniature Non-Contact Temperature Sensor   Yes   358,020

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ