ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > ¿Âµµ Temperature > Æ®·£½º¹ÌÅÍ Transmitter¤¤
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
RY449111 J-Type Thermocouple Sensor
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
This compact low cost sensor does not sacrifice accuracy or repeatability. Choose J or K thermocouple output—or voltage output if your application is susceptible to noise or requires a long cable run.

Rugged and reliable
Designed for easy integration into standard 4 wire systems, the CI¡¯s onboard electronics are protected by a rugged NEMA 4 stainless steel housing. Compare this to the plastic housings used on other small IR sensors.

Thermal shock and temperature coefficient specifications are also outstanding for a sensor this small. And the 4:1 optics, 300mSec response time, and ¡¾1% repeatability all help assure fast, accurate measurements.

Offset errors eliminated
Because the CI has the same 50 ohm output impedance as a thermocouple, it functions accurately, when used in conjunction with the thermocouple break protection circuitry in most controllers, displays, and transmitters.

Wide selection of accessories
A variety of mounting and protective accessories make installation easy and help assure reliable operation in high ambient temperatures and demanding industrial environments.

Compact, easy to install and accurate. All reasons the CI is ideal for both OEM and end-user applications. You won¡¯t find a better value in a low cost IR sensor.

 
SPECIFICATIONS

GENERAL

Repeatability ¡¾1% of reading
Resolution (temp) <0.5¡ÆC (1¡ÆF)
Response time 350mSec (95% response)
Resolution (optical) 4:1 @ 90% energy
Spectral Response 7-18¥ìm
Emissivity Fixed at 0.95
Outputs  J or K thermocouple or10mV/¡ÆC linear voltage
Power 12-24 VDC @ 20 mA
ENVIRONMENTAL
Environmental rating IP 65, NEMA 4
Ambient temp range 0 to 70¡ÆC (32 to 160¡ÆF)
With air cooling 0 to 90¡ÆC (32 to 200¡ÆF)
With water cooling 0 to 260¡ÆC (32 to 500¡ÆF)
MECHANICAL
Construction Stainless steel housing
Cable length 1m (3 ft)

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
RY449111   CI1A   TYPE J THERMOCOUPLE SENSOR (0-350 DEG C)   Yes   321,300
RY449112   CI2A   TYPE K THERMOCOUPLE SENSOR (0-350 DEG C)   Yes   321,300
RY449113   CI3A   VOLTAGE OUTPUT SENSOR (0-350 DEG C)   Yes   321,300
RY449114   XXXCIACFB   OPTIONAL FIXED MOUNTING BRACKET FOR Compact Non-Contact Temperature Sensors   Yes   45,900

 

RY449117   XXXCIACAP   OPTIONAL AIR PURGE COLLAR FOR Compact Non-Contact Temperature Sensors   Yes   64,260

 

RY449118   CIACWC   OPTIONAL COOLING JACKET (REQUIRE HITEMPCABLE *) FOR CI OPTION "W" ** FOR Compact Non-Contact Temperature Sensors   Yes   73,440

 

RY449115   XXXCI1CON   OPTIONAL THERMOCOUPLE CABLE EXT. KIT FOR CI1 FOR Compact Non-Contact Temperature Sensors   Yes   45,900

 

RY449131   XXXCI2CON   OPTIONAL THERMOCOUPLE CABLE EXTENSION CONN.KIT FOR CI2 FOR Compact Non-Contact Temperature Sensors   Yes   45,900

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ