Humidity&Temperature Meter with rechargeable US AC-adapter,MI70 Link software,analog output–signal cable |
The unit is
designed for spot-checking humidity measurements. It is ideal for field
checking and calibration of transmitters. The multilingual, menu-based
interface is easy to use, and a clear graphical LCD display with
datalogger function provides an easy way to handle measurement data.
Three (3) probes are available for a variety of applications. Dewpoint
and carbon dioxide probes can be connected as well for application such
as greenhouse monitoring and health inspection. One or two probes can be
connected at a time.
The unit has three (3) optional humidity probes: VA703227, VA703228, and
VA703229. VA703230 is a general-purpose probe for humidity measurements
between -20 and +60¡ÆC. The VA703228 is a long, stainless steel probe
for humidity measurements between -50 and +120¡ÆC, especially suitable
for spot-checking in ducts. The VA703229 probe has a small sensor head
at the end of a 5-meter cable, ideal for difficult-to-reach areas. |
|
Features
|
- Rugged,
reliable design with Graphical Backlit LCD
- Polymer-based
sensor provides accuracy, reliability, long-term stability,
and fast response
- ¡¾1%
accuracy from 0 . . . 100%RH
- Multilingual
user interface
- Displays
various humidity parameters
- Sensor
preheat and chemical purge options for demanding application
- Multiprobe
Operation: Up to (2) Dewpoint, CO2, or Humidity
probes can be connected
- (3)
probes, temperature ranges between -70 and +180¡ÆC
- Display
and Print Data Shows measurement trends graphically on
display
- Log
Data and Download into a PC via Link Software
|
|
|
SPECIFICATIONS
Power
Supply |
Rechargeable
NiMH with AC power or (4) AA alkaline Life: 48 h continuous battery use |
Analog Output |
0¡¦1
VDC (0.6 mV resolution) |
Data Logging
Capacity |
2,700
points |
Housing
Classification |
IP54 |
Weight |
400 g |
Relative Humidity
Measurement Range |
0¡¦100%
RH |
Accuracy, Over
Temperature Range(including nonlinearity, hysteresis and repeatability) |
-40
¡¦ +180¡Æ C |
Max.
Accuracy When Calibrated Against High Quality Certified Humidity
Standards: |
|
0¡¦90%RH |
+1%RH |
|
90¡¦100%RH |
+2%RH |
When
Calibrated Against Salt Solutions (ASTM E104-85) |
|
0¡¦90%RH |
+2%RH |
|
90¡¦100%RH |
+3%RH |
Response
Time (90%) @ 20¡Æ C Still Air |
|
0¡¦90%RH |
+2%RH |
|
90¡¦100%RH |
+3%RH |
Sensor Stability
HUMICAP® 180 |
Better
than 1% RH / year |
Temperature
Measurement Range |
|
HMP75 |
-20 ¡¦ +60¡Æ C |
|
HMP76 |
-50 ¡¦+120¡Æ C ;
Short Time -50 ¡¦+180¡Æ C |
|
HMP77 |
-70 ¡¦ +180¡Æ C |
Calculated
Variables |
|
Dewpoint
Temperature |
-40 ¡¦ +100¡Æ C |
|
Mixing Ratio |
0¡¦600g/kg
dry air |
|
Absolute Humidity |
0¡¦600 g/m3 |
|
Wet Bulb
Temperature |
0¡¦100¡Æ C |
|
Enthalpy |
0¡¦160 kI/g |
|
Water Vapor
Pressure |
0¡¦1000 hPa |
CAT
NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
VA703220 |
|
HM70D3 |
|
Humidity
& Temperature Meter with rechargeable US AC-adapter, MI70 Link
software and analog output – signal cable |
|
Yes |
|
1,890,000
|
VA703221 |
|
HM70K3 |
|
Humidity
& Temperature Meter with alkaline batteries only, MI70 Link software
and analog output – signal cable |
|
Yes |
|
1,717,200
|
VA703222 |
|
HM70D0 |
|
Humidity
& Temperature Meter with rechargeable US AC-adapter, no indicator
accessories |
|
Yes |
|
1,674,000
|
VA703223 |
|
HM70K0 |
|
Humidity
& Temperature Meter with alkaline batteries only, no indicator
accessories |
|
Yes |
|
1,587,600
|
VA703227 |
|
HMP75 |
|
General
Purpose Humidity probe, -20 to 60¡Æ C |
|
Yes |
|
1,317,600
|
VA703228 |
|
HMP76 |
|
Long
Stainless Steel Humidity probe -50 to 120¡Æ C |
|
Yes |
|
1,609,200
|
VA703229 |
|
HMP77 |
|
Small sensor
Humidity probe up to 180¡Æ C |
|
Yes |
|
1,933,200
|
VA703224 |
|
MI70LINK |
|
OPTIONAL
MI70Link (software with RS232 cable)
FOR Humidity and Temperature Meter |
|
Yes |
|
129,600
|
VA703225 |
|
¡¡ |
¡¡ |
OPTIONAL
Analog output-signal cable
FOR Humidity and Temperature Meter |
|
Yes |
|
75,600
|
VA703226 |
|
¡¡ |
¡¡ |
OPTIONAL
MI70Link and analog output-signal cable
FOR Humidity and Temperature Meter |
|
Yes |
|
205,200
|
VA703231 |
|
¡¡ |
¡¡ |
OPTIONAL
Probe holder for VA703228/76B
FOR Humidity and Temperature Meter |
|
Yes |
|
54,000
|
VA703232 |
|
¡¡ |
¡¡ |
OPTIONAL
Connection cable to 60/70/140 series
transmitters FOR Humidity and Temperature Meter |
|
Yes |
|
86,400
|
VA703233 |
|
¡¡ |
¡¡ |
OPTIONAL
Connection cable to HMP230 series / HMP228
FOR Humidity and Temperature Meter |
|
Yes |
|
86,400
|
VA703234 |
|
¡¡ |
¡¡ |
OPTIONAL
Connection cable to 20/30/130 series
transmitters FOR Humidity and Temperature Meter |
|
Yes |
|
86,400
|
VA703235 |
|
¡¡ |
¡¡ |
OPTIONAL
Connection cable to HMT300 series
FOR Humidity and Temperature Meter |
|
Yes |
|
86,400
|
VA703236 |
|
¡¡ |
¡¡ |
OPTIONAL
Carrying case for indicator and probe
(VA703227/VA703228/VA703229) FOR Humidity and
Temperature Meter |
|
Yes |
|
270,000
|
| |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|