VA100381 Humidity and Temperature Indicator
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:VA100381
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
Humidity and Temperature Indicator with standard Temperature probe,also includes a calibration option
Humidity Measurement for Professionals
In addition to displaying the humidity and temperature readings, the HMI41 can calculate dewpoint and wet bulb temperature, absolute humidity and mixing ratio — no more awkward conversion tables or complex calculations.

The indicator has an easy-to-read two-line liquid crystal display. The display units (metric or non-metric) are easily selected.

Field Calibrator
The HMI41 indicator also includes a calibration option. The combination of HMI41 indicator and HMP46 humidity and temperature probe is the best choice for calibrating most humidity transmitters in the field at one point quickly and easily.
 
Applications
  • The HMI41 hand-held indicator fitted with the HMP46 probe can be used for spot checking humidity and temperature in applications such as:
  • Plant Maintenance
  • Installation and inspection of air conditioning systems
  • Production and storage areas — freezers, cool stores and containers
  • Production processes in temperatures of up to +180¡ÆC
  • Monitoring the drying of structures after water damages of during construction
 
SPECIFICATIONS

Indicator

Maximum error of Humidity ¡¾0.1%RH
indicator at +20 ¡ÆC Temperature ¡¾0.1¡ÆC
Calculated variables dewpoint temperature, absolute humidity, wet bulb temperature, mixing ratio
Resolution 0.1 %RH; 0.1¡ÆC
Power supply 4 batteries, type IEC LR 6
Battery operation time 72 h continuous use with alkaline batteries
Operating temperature -20 to +60 ¡ÆC
Operating humidity non-condensing
Storage temperature -40 to +70¡ÆC
Display two line LCD
Weight (with batteries) 300 g
High Temperature RH/Temp. Probe
Humidity
Measurement range 0 to 100 %RH non-condensing
Maximum accuracy 0 to 90%RH ¡¾1 %RH
90 to 100%RH ¡¾2 %RH
Typical long-term stability better than 1 %RH/a
Response time (90%)at +20 ¡ÆC in still air 15 seconds
Temperature
Measurement range Continuous measurement -40 to +100¡ÆC
Short-term measurement -40 to +180¡ÆC
Accuracy at +20 ¡ÆC ¡¾0.2 ¡ÆC
Temperature sensor Pt 100 IEC 751 1/3 class B
Probe dimensions 12 mm X 320 mm
Handle 38 mm X106 mm
General
Typical ranges of calculated variables
  dewpoint temperature -40 to +100 ¡ÆC
  absolute humidity  0 to 600 g/m3
  wet bulb temperature 0 to +100 ¡ÆC
  mixing ratio  0 to 600 g/kg d.a.
Cable length 1500 mm - extended spiral cable
Operating temperature range for electronics -20 to +60 ¡ÆC
Probe head material stainless steel
Housing classification IP 65 (NEMA 4)
Sensor protection sintered filter, part no. 0195
Weight +50 g
Standard Probe
Temperature -4 to 140 ¡ÆF (-20 to 60 ¡ÆC)
Accuracy ¡¾0.15 ¡ÆC
Humidity same as high temp. probe
Dimensions 18 mm X 118 mm overall length - 237 mm

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
VA100381   HMI41/HMP45   HUMIDITY AND TEMPERATURE INDICATOR WITH HMP45 STANDARD TEMPERATURE PROBE   Yes   1,941,840

 

VA100380   HMI41/46   TEMPERATURE/HUMIDITY/DEWPOINT INDICATOR WITH HMP46 HIGH TEMPERATURE STAINLESS STEEL PROBE   Yes   2,149,200

 

VA100382   85-21797   OPTIONAL CARRYING CASE HMI41/45 OR 46 PROBE/ FOR Temperature / Humidity / Dewpoint Indicator   Yes   106,920

 

VA239603   HMK15   OPTIONAL RH CALIBRATION KIT FOR Temperature / Humidity / Dewpoint Indicator   Yes   1,293,840

 

VA100384   85-180   OPTIONAL REPLACEMENT SENSOR 85-HUMICAP 180 SENSOR FOR Temperature / Humidity / Dewpoint Indicator   Yes   291,600

 

VA100385   85-0195HM   OPTIONAL SINTERED FILTER, 133 MICRONS FOR 46 PROBE/ FOR Temperature / Humidity / Dewpoint Indicator   Yes   97,200

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ