DK976533 Temperature only, Type K-thermocouple
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:DK976533
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
Series A,Temperature only, Type K-thermocouple Fax Logger¢â with alarm
Take the guess work out of tracking critical processes. These units can be placed in your building across town or across the country. They deliver charts automatically to your fax machine or E-mail account, and send a fax when high or low temperature and/or humidity alarm conditions are met. They also send a fax when Ac power fails. The FX320¢â has a Type K-thermocouple remote probe and is perfect for hard to reach places such as freezers, ovens and more. The FX435¢â has a remote probe for chambers, clean rooms and more.

The FX320¢â is an excellent way to monitor HVAC/R Systems while the FX430¢â and FX435¢â can record and evaluate weather patterns.

To protect probe & increase life, please use dust filter in dusty environments or where RH exceeds 70%. Probe dust filter will slow down response time.

 
Features
  • User Selectable Faxing Intervals: 1 day, 7 day, 31 day
  • Alarm: Automatically sends a fax when user selectable high/low temperature and/or temperature/humidity conditions are met. Also sends a fax when AC power fails
  • Sample Points: 16,128 per channel
  • Sample Rate: Every 10 seconds
  • Sample Range: User selectable faxing intervals: 1 day, 7 day, 31 day
  • Auto Callback and Auto Line Seizure: The unit automatically seizes the phone line to make call outs and will continuously call every 15 minutes until it successfully completes the call
  • Display: LCD 8 x 2 characters
  • Power: 120V AC with 9V battery backup
  • Connection: Plugs into standard phone outlet (will not work through a PBX, digital phone system or with call waiting)
  • Dimensions: 7" x 5" x 2"
  • Weight: 1 lb.
  • Available E-mail Fax Service Providers as of 10/00: J2.com, Efax.com, Callwave.com, Faxsave.com, messageclick.com, faxpc.com, Tems.com
 
SPECIFICATIONS

Series B and C

Temperature Range 0 to 100¡ÆF
Temperature Accuracy ¡¾1.8¡ÆF
Humidity Range 0 to 95% Rh
Humidity Accuracy ¡¾2% RH at 73¡ÆF
Remote Probe (Series C) Temperature and humidity ranges and accuracy same as internal sensors
Remote Probe Dimensions 0.9" diameter, 5.9" long, 6' cable
Series A — Type K Thermocouple Model
Temperature Range 0 to 220¡ÆF (0 to 100¡ÆC)
Temperature Accuracy ¡¾1.8¡ÆF
Ambient Operating Conditions 0 to 122¡ÆF (-17.7 to +50¡ÆC)
Remote Probe Dimensions K-Thermocouple 4' bead wire probe with mini-connector

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
DK976533   FX320   Temperature only, Type K-thermocouple Fax Logger¢â with alarm   Yes   1,293,840

 

DK976531   FX430   Temperature & Humidity Fax Logger¢â with internal sensor & alarm   Yes   1,293,840

 

DK976532   FX435   Temperature & Humidity Fax Logger¢â with 6' remote probe & alarm   Yes   1,509,840

 

DK712   A712   OPTIONAL Locking wall mount case FOR Temperature/Humidity Fax Loggers with Alarm   Yes   127,440

 

DK976520   SW400   OPTIONAL Logger Calibration Software FOR Temperature/Humidity Fax Loggers with Alarm   Yes   602,640

 

DK015   A015   OPTIONAL DicksonWare¢â Software and Download cable FOR Temperature/Humidity Fax Loggers with Alarm   Yes   170,640

 

DK976530   A060   OPTIONAL Download Cable Only FOR Temperature/Humidity Fax Loggers with Alarm   Yes   127,440

 

DK880   A880   OPTIONAL 10' EXTENSION CABLE FOR Temperature/Humidity Fax Loggers with Alarm   Yes   105,840

 

DK881   A881   OPTIONAL 50' EXTENSION CABLE FOR Temperature/Humidity Fax Loggers with Alarm   Yes   170,640

 

DK882   A882   OPTIONAL 100' EXTENSION CABLE FOR Temperature/Humidity Fax Loggers with Alarm   Yes   213,840

 

DK976524   A867   OPTIONAL Probe dust filter* (FX430 & FX435 only) FOR Temperature/Humidity Fax Loggers with Alarm   Yes   54,000

 

DK1140041   D605   OPTIONAL 4 INCH PIERCING PROB, 5' COIL CABLE 4"X5/32")+1650F FOR Temperature/Humidity Fax Loggers with Alarm   Yes   170,640

 

DK1140042   D608   OPTIONAL 5" IMMERSION PROBE, 5' COILED CABLE +1650 F FOR Temperature/Humidity Fax Loggers with Alarm   Yes   192,240

 

DK1140043   A203   OPTIONAL 6" HIGH TEMPERATUR BASIC PROBE+2100 F FOR Temperature/Humidity Fax Loggers with Alarm   Yes   278,640

 

DK114005   D617   OPTIONAL 10' STRAIGHT EXTENSION CABLE FOR Temperature/Humidity Fax Loggers with Alarm   Yes   127,440

 

DK1140051   A202   OPTIONAL 100' STRAIGHT EXTENSION CABLE FOR Temperature/Humidity Fax Loggers with Alarm   Yes   365,040

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ