ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > À½¼º µ¥ÀÌÅÍ Voice/Data > Åë½Å Telecom

DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
BD21150 Voice Network Analyzer
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:BD21150
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
The BD21150 and BD21151 are designed for use during the installation or activation of a new system
The BD21150 and BD21151 are designed for use during the installation or activation of a new system, or when qualifying existing pairs for new services or when troubleshooting an existing system.

BD21150: Bridges the gap between general purpose multimeters and expensive transmission test equipment; specifically designed as a multi-purpose test set for installation and maintenance work in a telephone environment.
 
BD21151 Features
  • Tests for line voltage and current, noise, balance, loss and slope, as well as providing complete Caller ID and Call Waiting testing
  • The Caller ID and Call Waiting features are unique in one unit and include ring time, silent time, alert-to-carrier time, mark and space dB, checksum, CAS tone dB, ACK tone dB and OSI time
  • Line Measurements – simultaneously monitor interaction of line voltage, loop current, and ringer voltage
  • Internal 430 Ohm Load – a 430 ohm resistive load is required for testing loop current for conformance standards
  • Loss & Slope – determined on a phone line (frequency / dB level of any tone)
  • Noise & Balance Measurements – uncover noise and balance problems by simultaneously displaying metallic noise, noise to ground and longitudinal balance
 
BD21150 Features
  • Line Measurements –make simultaneous measurements of line voltage, loop current, dB level and frequency.; allows user to monitor interaction between these parameters
  • Ohms Mode – Measure resistance of unpowered phone loops and other passive circuits
  • Loop Mode – measures effective resistance of a powered phone line
  • Loss & Slope – determines loss & slope on a phone line (frequency of tone / True RMS level)
  • Tone Generator – 1004 Hz, 0 dBm tone allows simple cable identification and mapping
  • Digit Monitor – provides monitoring and analysis of DTMF and pulse digits for verifying proper dial-up performance
 
SPECIFICATIONS
BD21150 DC Volts Min/Max DC mA Min/Max AC Volts Min/Max Decibels Min/Max Frequency Min/Max DC Ohms Min/Max Loop Ohms Min/Max
Range ¡¾1 / +99.5 ¡¾1 / +99.5 3 / 125 -44 / +4 dBm 15 / 8K Hz 0 / 25K 100 / 5K
Resolution 0.05 0.05 1 from 0.5 to 6.0 16 100 100
Accuracy ¡¾1.0 % f.s. ¡¾1.0 % f.s. ¡¾2.0% f.s. 16 ¡¾2.0% f.s.
BD21151 Minimum Maximum         ¡¡
Line Measurement Mode      
Line Volts 0 100 V dc         ¡¡
Loop current 0 100 Ma dc         ¡¡
Ringing Voltage 150 V ac           ¡¡
Loss/Slope Measurement Mode     
DB Level -34 0 dBm         ¡¡
Frequency 300 3000 Hz         ¡¡
Noise Measurement Mode      
Metallic Noise 10 40 dBmC         ¡¡
Noise to Ground 60 94 dBmC         ¡¡
Longitudinal Balance 54 84 dB         ¡¡
Line Termination 600 Ohms + 2.2 (micro) F        ¡¡ ¡¡
Primary Tests for Installation Verification/Troubleshooting for Fault Locating   
Application    

BD21150

BD21151

    ¡¡
Tone Generation    

X

    ¡¡
Determine Loop Length & Resistance   ¡¡

X

— 

  ¡¡ ¡¡
Identify Opens, Shorts, Grounds
& Crosses
  ¡¡

X

  ¡¡ ¡¡
Conduct Noise measurements   ¡¡

  ¡¡ ¡¡
Perform Loss/Slope Measurements   ¡¡

X

  ¡¡ ¡¡
Perform Line Measurements    

X

X

    ¡¡

CAT NO. MODEL DEscRIPTION AVAIL PRICE
BD21150   BVA 70   Voice Network Analyzer Includes Carrying Pouch, leads, User Guide   Yes   1,198,800 
Included Accessories: Carry Pouch; Cable patch cord with clip, 3ft.; Ground cable and User Guide
BD21151   CWT 150   Transmission Impairment/CIDCW Tester Includes Carrying Pouch, leads, User Guide   Yes   1,285,200

 

Included Accessories: Carry Pouch; Cable patch cord with clip, 3ft.; Ground cable and User Guide
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ