ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > Àü±â ¹× Àü·ÂÃøÁ¤±â > HT - italia

 
Multitest 75 ´Ù±â´É ¸ÖƼ¸ÞŸ
    ¡¤ °í°´¼±È£µµ :
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)

Multifunction TRMS DMM for voltage AC/DC, Current AC, Frequency, Resistance measurements, Safety test on electrical plants and Wire mapping Test on LAN cables.

MULTITEST model M75 is an innovative instrument which joins together DMM, Safety Tester and LAN Checker features inside a compact and ergonomic user-friendly structure and with an extremely reduced weight (800g only).

The True RMS DMM is a professional instrument with True RMS measurement of AC/DC Voltage, AC/DC Current (through external clamp), Resistance and Frequency. Additional features are MAX/MIN/AVG function, HOLD function and PEAK detection with Response Time of 1ms, useful for surge current detection.

The Safety Tester features allow to perform test on electrical plants according to VDE0413. Continuity, insulation, global earth resistance, RCD's, phase sequence indication and phase coincidence using only one test lead - by just touching cables, even insulated - or two test leads. The innovative AUTO function permits to perform automatically the main safety tests on a plant (namely earth resistance, RCD's, insulation) by just connecting the instrument to a socket and pressing the START button, with a final response of OK or NOT OK.

LAN Checker detection of correct or incorrect wire mapping of a LAN cable with extremely simple indications about the errors found, to guide you step by step through the troubleshooting.
 

Model Multitest M75 DMM and LAN Tester
DMM Section
  • DC Voltage.
  • AC True RMS Voltage.
  • AC True RMS Current with External Clamp.
  • AC True RMS Leakage Current with external clamp (optional).
  • DC Current.
  • Resistance.
  • Continuity test with buzzer.
  • Frequency with test leads.
  • Frequency with External Clamp.
  • MIN/MAX/ AVG functions.
  • PEAK function with response time 1ms.
  • HOLD function.

 

 

 



Test Section
  • Continuity test of protective conductors with 200mA test current.
  • Insulation Resistance with a test voltage of 500V DC.
  • Tripping time of RCD's type AC with 30mA, 30mA x 5, 100mA, and 300mA test current.
  • Global earth resistance without RCD tripping.
  • Phase coincidence with 1 test lead only or with two test leads.
  • AUTOTEST function automatic sequence test of Global Earth Resistance + RCD test + Insulation test with OK/NOT OK functions.

  • Test executed on twisted pair cables UTP and STP with RJ45 connector.
  • Wire mapping control of following wrong conditions:
    OPEN, SHORT, CROSS, REVERSE, SPLIT, MISWIRE message display.
  • Quick selection of cable pairs.
  • Automatic detection of remote control units (from #1 to #8).
  • AutoPower OFF.
  • Low battery indicator.

 

  • HT4003 400A AC Clamp.
  • C2075 (Shuko cable ending with two safety banana plugs).
  • KIT0075 (kit of two test leads and two alligator clips).
  • Remote identifier #1 CH1.
  • Remote identifier #2 CH2.
  • YAAMS000000 3 patch cables, 30cm, RJ45 to RJ45.
  • BORSA75 Carrying case.
  • ISO9001 Calibration certificate.
  • English instruction manual.

  • HT96U 1-100-1000A/1V leakage current clamp (jaw opening 54mm max. dia.).
  • NOCANBA adapter (for connection to HT96U clamp).
  • REM38 No.6 Remote identifier unit #3, #4, #5, #6, #7, #8.
  • REM3 remote unit #3 + connection cable RJ45-RJ45.
  • REM4 remote unit #4 + connection cable RJ45-RJ45.
  • REM5 remote unit #5 + connection cable RJ45-RJ45.
  • REM6 remote unit #6 + connection cable RJ45-RJ45.
  • REM7 remote unit #7 + connection cable RJ45-RJ45.
  • REM8 remote unit #8 + connection cable RJ45-RJ45.

CE mark
EN 61557-4 Continuity Test
EN 61557-2 Insulation Resistance
EN 61557-5 Earth Resistance
EN 61557-6 RCD Test
EN 61326    EMC Standards
EN 61008
EN 61009

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ