| The Gemini R is a blackbody source with which radiation pyrometers, commonly referred to as IR sensors, can be calibrated. With a temperature range of 50ºC to 550ºC, the temperature of the cavity can be set with 0.1ºC resolution. The temperature of the furnace is set and indicated on a PID controller. An independent indicator is also provided for higher accuracy with a standard probe, which indicates the actual radiance temperature. Temperature variation over a 5-minute period, as viewed on the temperature controller, is ±0.2ºC and a radiation thermometer directed into the cavity detects similar variations.
The Gemini R’s cavity’s size is 2.5" Ø x 6.3" deep (65mm x 160mm). Maximum temperature differences are ±1ºC in the range of 100ºC to 500ºC. The Gemini R is capable of accepting blackbody fixed points to achieve the highest level of a radiation measurement possible. Typical fixed-point uncertainties are ±0.25ºC. Gallium, indium, tin and zinc cells are available.
Emissivity is greater than 0.995, and traceability may be established with a NIST certificate for the built-in indicator and/or supplied probe. The Gemini R can be supplied with RS232 or RS422 communications.
A compact furnace for calibrating radiation pyrometers, the Pegasus R sets the temperature of the furnace on a controller while an independent indicator, whose sensor is built into the furnace’s cavity, indicates the actual radiance temperature. The cavity’s diameter is 0.8" (20mm). The depth is 2.6" (65mm). The emissivity is 0.995. The cavity is removable and a fixed-point cell may be put in its place.
A Blackbody Target Radiation Source is housed within the Pegasus R for the calibration of radiation thermometers in the wavelength range of 9 to 14 micrometers. Incorporating suitable insulation within its design, this radiation source’s aperture is 0.4" (10mm) in diameter. A scan across the aperture at 444ºC demonstrates the source is uniform to better than 0.3ºC. Traceability may be established with a NIST certificate for the built-in indicator and supplied probe.
The Pegasus R’s temperature range is 150ºC to 1200ºC and it has a stability of 0.1ºC. Time to temperature is 20 minutes. It weighs only 15 lb. and is easily carried in the field for on-site use. The Pegasus R can be supplied with either RS232 or RS422 communications. |
| |
|
Features |
- Medium & High Temperature Radiation Pyrometer Primary Source
- 0.995 Emissivity
- Accepts Fixed Point Cells
- NIST Certificate for the built-in Indicator and supplied probe
|
| | | SPECIFICATIONS
|
Model |
GR |
PR |
| Temperature Range |
50 to 550°C (122 to 1022°F) |
150 to 1200°C (302 to 2192°F) |
| Emissivity |
Greater than 0.995 |
0.995 |
| Stability |
±0.1°C |
±0.1°C (±.18°F) |
| Display Resolution |
0.1°C |
1°C |
| Cavity Size |
2.5" Ø x 6.3" deep (65mm Ø x 160mm) |
.8" Ø x 2.6" deep (20mm Ø x 65mm) |
| Time to Temperature |
45 minutes |
20 minutes |
| Power |
1000 watts typical, 100-130 or 208-240V AC, 50/60Hz |
2.3kW typical, 100-130 or 208-240V AC, 50/60Hz |
| Dimensions |
12.2" x 10.4" x 7.9" |
12.3" x 10.5" x 8" |
| Weight |
22 lb. |
15 lb. |
| CAT NO. |
 |
MODEL |
 |
DEscRIPTION |
 |
AVAIL |
 |
PRICE |
| TT60100 |
|
Pegasus-R |
|
High Temperature Black-Body Calibrator including standard probe |
|
Yes |
|
14,412,600
|
| TT60101 |
|
Gemini-R |
|
Radiation Calibrator including standard probe |
|
Yes |
|
10,208,160
|
| TT60102 |
|
Gemini-R-INS-FG |
|
OPTIONAL Gallium Hockey Puck Cell FOR Infrared Thermometer Calibrators |
|
Yes |
|
4,590,000
|
| TT60103 |
|
Gemini-R-INS-FI |
|
OPTIONAL Indium Hockey Puck Cell FOR Infrared Thermometer Calibrators |
|
Yes |
|
4,590,000
|
| TT60104 |
|
Gemini-R-INS-FZ |
|
OPTIONAL Zinc Hockey Puck Cell FOR Infrared Thermometer Calibrators |
|
Yes |
|
4,590,000
| | |
|
|
 | |
 |
|
 |
|
이 상품에 대한 사용후기가 아직 없습니다.
사용후기를 작성해 주시면 다른 분들께 많은 도움이 됩니다. |
|
 |
|
 |
|
|
 | |
 |
|
 |
|
이 상품에 대한 질문이 아직 없습니다.
궁금하신 사항은 이곳에 질문하여 주십시오. |
|
 |
|
 |
|
|
|